Training
Proline t-mass F 300
Thermal mass flowmeter
Inline flowmeter with long-term stability and a compact, easily accessible transmitter
The patented sensor design of t-mass F provides unprecedented measurement stability in thermal inline mass flow measurement. It compensates in real time for changes of process conditions: temperature, pressure, flow direction and gas type. Its compact transmitter offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology ensures measurement reliability and compliant verification.
- F
- L
- E
- X
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Max. measurement error
Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)
-
Measuring range
0.5 to 3750 kg/h (1.1 to 8250 lb/h)
-
Medium temperature range
-40 °C to +180°C (-40 °F to +356 °F)
-
Max. process pressure
PN40 / Cl. 300 / 20K
-
Wetted materials
Measuring tubes
DN 15 to 50 (½ to 2"): stainless cast steel, CF3M/1.4408
DN 65 to 100 (2½ to 4"): stainless steel, 1.4404 (316/316L)
Process connections
Flange connections
Stainless steel, 1.4404 (F316/F316L)
Threaded connections
Stainless steel, 1.4404 (316/316L)
Sensing element
Unidirectional
Stainless steel, 1.4404 (316/316L)
Alloy C22, 2.4602 (UNS N06022);
Bidirectional
Stainless steel, 1.4404 (316/316L)
Reverse flow detection
Stainless steel, 1.4404 (316/316L)
-
Quick selection
Individual configuration
-
Benefits
Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof
High level of process control – premium measurement accuracy and repeatability
Reliable monitoring – detection of process disturbances and reverse flow
...
-
Field of application
Measuring principle is characterized by a high operable flow range and direct mass flow measurement
Measurement of utility and process gases as well as gas mixtures in small line sizes
Device properties
Inline version with DN 15 to 100 (1/2 to 4")
...
Documents / Manuals / Software
-
Proline t-mass F 300
Thermal mass flowmeter
Technical Information (TI) -
Proline t-mass F 300
Modbus RS485
Thermal mass flowmeter
Operating Instruction (BA) -
Proline t-mass F 300
HART
Thermal mass flowmeter
Operating Instruction (BA) -
Proline t-mass 300
Modbus RS485
Thermal mass flowmeter
Device Parameter (GP) -
Proline t-mass 300
HART
Thermal mass flowmeter
Device Parameter (GP) -
Proline 300
Modbus RS485
Transmitter with thermal mass flowmeter sensor
Short Instruction (KA)09/20English -
Proline 300
HART
Transmitter with thermal mass flowmeter sensor
Short Instruction (KA)09/20English -
Proline t-mass F
Thermal mass flowmeter sensor
Short Instruction (KA)09/20English -
Kit wireless antenna for extended range
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital,
t-mass 300, 500-digitalInstallation Instructions (EA) -
Alteration to Display module, to Display module with WirelessHART or
Display module with WLAN
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital,
t-mass 300, 500-digitalInstallation Instructions (EA) -
Replacing the terminal connection
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digitalInstallation Instructions (EA) -
Replacing the transmitter
t-mass 300
Installation Instructions (EA) -
Replacing ISEM electronics module, ISEM extender, ribbon cable
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digitalInstallation Instructions (EA) -
Replacing RJ45-M12 Adapter
Proline 300, 500-digital
Installation Instructions (EA) -
Weather Protection
Promag, Promass 300, 500, Prosonic Flow, t-mass 300
Installation Instructions (EA) -
Protective Cover connection compartment
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digitalInstallation Instructions (EA) -
Replacing cover for remote display module, O-ring for cover
Promag, Promass, Prosonic Flow, t-mass 300
Installation Instructions (EA) -
Replacing Spare Parts
Promag, Promass 100, CNG-, LNG-, LPGmass, Promag 400 Index C, Proline
300, 500, 500-digital, Prosonic Flow E 100, Prosonic Flow E He
at, Prosonic Flow, t-mass 300, 500-digitalInstallation Instructions (EA) -
Activating application packages, switching the I/O function, upgrading
with additional I/O hardware
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital,
t-mass 300, 500-digitalInstallation Instructions (EA) -
Alteration with display and operating module DKX001
Promag, Promass, Prosonic Flow, t-mass 300
Installation Instructions (EA) -
Replacing the electronics
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digitalInstallation Instructions (EA) -
Replacing cover, O-ring cover, Interface gasket
Promag, Promass 300, 500, Prosonic Flow, t-mass 300
Installation Instructions (EA) -
Replacing the display module
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digital, DKX001–Installation Instructions (EA) -
Proline t-mass 300
ATEX:
II3G
IECEx:
Zone 2Ex Safety Instructions (XA) -
Proline t-mass 300
Class I, Zone 1
Zone 21Ex Safety Instructions (XA) -
Proline t-mass 300
Class I Zone 2
Class I Division 2Ex Safety Instructions (XA) -
Proline t-mass 300
ATEX:
II1/2G
IECEx:
Zone 1/2Ex Safety Instructions (XA) -
Proline t-mass 300
Cl. I, II, III Div.1 for XP
Ex Safety Instructions (XA) -
Proline t-mass 300
HART
Web server
Special Documentation (SD) -
Proline t-mass 300
Modbus RS485
Web server
Special Documentation (SD) -
Proline t-mass 300
HART
Heartbeat Verification + Monitoring application package
Special Documentation (SD) -
Proline t-mass 300
Functional Safety Manual
Special Documentation (SD) -
Proline t-mass 300
Modbus RS485
Heartbeat Verification + Monitoring application package
Special Documentation (SD) -
Display modules A309/A310
Display with WLAN interface
Special Documentation (SD) -
Proline t-mass F/I 300/500 (e-book – PC version)
The flowmeter with long-term stability and a keen sense for utility
gasesCompetence Brochure (CP)11/20English -
Proline t-mass F/I 300/500 (e-book – Tablet version)
The flowmeter with long-term stability and a keen sense for utility
gasesCompetence Brochure (CP)09/20English -
Proline t-mass F/I 300/500
Le débitmètre pour les gaz d'une grande précision avec une excellente
stabilitéInnovations (IN)09/20fr -
Proline t-mass F/I 300/500
Das langzeitstabile Durchflussmessgerät mit dem feinen Gespür für
VerbrauchsgaseInnovations (IN)09/20German -
Proline t-mass F/I 300/500
The flowmeter with long-term stability and a keen sense for utility
gasesInnovations (IN)09/20English -
EDD Single, FDM_HART_FL_t-mass300500_0x1160_0x01_0x01, 30.10.2020 (Flow, t-mass 300 500, 0x1160)
HART,
Experion Version: R500Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, T-mass300500_HART_FW1_00_zz_Dev_Rev_1, 30.10.2020 (Flow, t-mass 300 500, 0x1160)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R511
Field Xpert - SMT70 Version: 1.04.00
FieldCare Version: 2.15.00
PACTware Version: 5.0
Plant Resource Manager Version: R4.03Device Type Manager (DTM)1.45.0.280Language neutral -
DTM Single, T-mass300500_CDI_FW1_00_zz_Dev_Rev_1, 30.10.2020 (Flow, t-mass 300 500, 0x6460)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.04.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.45.0.127Language neutral -
DTM Single, T-mass300500_MR4_FW1_00_zz_Dev_Rev_1, 30.10.2020 (Flow, t-mass 300 500, 0x6460)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.04.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.45.0.127Language neutral -
Faceplate Single, PRM_HART_FL_t-mass300500_0x1160_0x01_0x01, 30.10.2020 (Flow, t-mass 300 500, 0x11
HART,
Plant Resource Manager Version: R4.02Faceplate1.00.00Language neutral -
T-MASS F, T-MASS I
Product Code: 6F3B-, 6F5B-, 6I3B-, 6I5B-
Declaration Number: HE_01371_01.20
Manufacturer Specification:Manufacturer DeclarationGerman , English -
T-MASS F, T-MASS I
Product Code: 6F3B-, 6F5B-, 6I3B-, 6I5B-
Declaration Number: EC_00805_01.20EU DeclarationGerman , English , fr -
T-MASS F, T-MASS I
Product Code: 6F3B-, 6F5B-, 6I3B-, 6I5B-
Declaration Number: EC_00808_01.20EU DeclarationGerman , English , fr -
T-MASS F
Product Code: 6F3B-, 6F5B-
Declaration Number: EC_00823_01.20EU DeclarationGerman , English , fr -
T-MASS F, T-MASS I
Product Code: 6F3B-, 6F5B-, 6I3B-, 6I5B-
Declaration Number: EC_00806_01.20EU DeclarationGerman , English , fr -
T-MASS F, T-MASS I
Product Code: 6F3B-, 6F5B-, 6I3B-, 6I5B-
Declaration Number: EC_00810_01.20EU DeclarationGerman , English , fr -
T-MASS F, T-MASS I
Product Code: 6F3B-, 6F5B-, 6I3B-, 6I5B-
Declaration Number: EC_00807_01.20EU DeclarationGerman , English , fr -
T-MASS F, T-MASS I
Product Code: 6F3B-, 6F5B-, 6I3B-, 6I5B-
Declaration Number: EC_00809_01.20EU DeclarationGerman , English , fr -
T-MASS I, T-MASS F, t-mass, PROSONIC FLOW P, Prosonic Flow G, LNGmass, Dosimass
Product Code: 65F-, 65I-, 6F3B-, 6F5B-, 6I3B-, 6I5B-, 8E-, 9G3B-, 9G5B-, 9P5B-, D8LB-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02228/20MiscellaneousRussian -
t-mass T, Prowirl R, Prowirl O, Prowirl F, T-MASS I, T-MASS F, t-mass B, t-mass A, t-mass, Prowirl D, PROSONIC FLOW P, Prosonic Flow G, PROSONIC FLOW E, Prosonic Flow 93, Prosonic Flow B, Prosonic Flow 92, Prosonic Flow 91, PICOMAG, Magphant, Dosimass, Promass 40, Promag D
Product Code: 92F-, ODMA-, 7R2B-, 7F2B-, 93P-, 93W-, 7O2B-, 7D2B-, 7O2C-, 7F2C-, 7R2C-, 65I-, 93C-, 7D2C-, 65F-, 93TA1-, 9B2B-, 9E1B-, 9EHB-, 9G3B-, 9G5B-, 9P5B-, DMA-, DTI200-, DTT31-, DTT35-, DTT35L-, DTT31L-, 91W-, 8E-, 6TAB-, 6I5B-, 6I3B-, 6F5B-, 6F3B-, 6BAB-, 6AAB-, 5D4C-, 40E-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EACE N RU-D.CH.AD07.B.02246/20MiscellaneousRussian -
t-mass, t-mass A, t-mass B, T-MASS F, T-MASS I
Product Code: 65F-, 65I-, 6AAB-, 6BAB-, 6F3B-, 6F5B-, 6I3B-, 6I5B-
Region/Country: Russia (TR CU)
Approval Number: EAEC N RU D-CH.AD07.B.03271/20MiscellaneousRussian -
Promass K, Promass O, Promass P, Promass Q, Promass S, Promass X, Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93, Prosonic Flow G, Prowirl D, Prowirl F, Prowirl O, Prowirl R, t-mass, t-mass A, t-mass B, T-MASS F, T-MASS I, Promass I, CNGmass, Dosimag, Dosimass, LNGmass, LPGmass, Promag 10, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W, Promass 40, Promass 80, Promass 83, Promass 84, Promass E, Promass F, Promass H
Product Code: 8I3B-, 8I1B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 8E5B-, 8E3B-, 8E2C-, 8E2B-, 8E1C-, 8E1B-, 8E-, 84X-, 84F-, 83X-, 83F-, 80F-, 7R2C-, 8I5B-, 8K1B-, 8O3B-, 8O5B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S1C-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 91W-, 92F-, 93C-, 93W-, 9G3B-, 9G5B-, DDA-, 7R2B-, 10D-, 10E-, 10H-, 10L-, 10P-, 10W-, 40E-, 5D4B-, 5D4C-, 5E1B-, 5E2B-, 5H-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 6I5B-, 6I3B-, 6F5B-, 6F3B-, 6BAB-, 6AAB-, 65I-, 65F-, 5W8C-, 5W8B-, 5W5B-, 5W4D-, 5W4C-, 5W4B-, 5W3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.03271/20MiscellaneousRussian -
T-MASS F, T-MASS I
Product Code: 6F3B-, 6F5B-, 6I3B-, 6I5B-
Region/Country: Canada
Approval Agency: CSAExplosion ProtectionEnglish -
T-MASS F, T-MASS I
Product Code: 6F3B-, 6F5B-, 6I3B-, 6I5B-
Region/Country: International (IECEx)
Approval Agency: CSA
Protection: Ex ecExplosion ProtectionEnglish -
T-MASS F, T-MASS I
Product Code: 6F3B-, 6F5B-, 6I3B-, 6I5B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/1/A,B,C,D,E,F,GExplosion ProtectionEnglish -
T-MASS F, T-MASS I
Product Code: 6F3B-, 6F5B-, 6I3B-, 6I5B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,DExplosion ProtectionEnglish -
T-MASS I, T-MASS F, PROSONIC FLOW P, Prosonic Flow G, Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Cubemass C
Product Code: 8Q5B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 9G3B-, 9G5B-, 9P5B-, O8E3B-, O8E5B-, O8F3B-, O8F5B-, O8O3B-, O8O5B-, O8Q3B-, O8Q5B-, O8X3B-, O8X5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8C5B-, 8C3B-, 6I5B-, 6I3B-, 6F5B-, 6F3B-
Region/Country:
Approval Agency:Explosion ProtectionEnglish -
T-MASS F, T-MASS I
Product Code: 6F3B-, 6F5B-, 6I3B-, 6I5B-
Region/Country: Canada
Approval Agency: CSAExplosion ProtectionEnglish -
T-MASS F, T-MASS I
Product Code: 6F3B-, 6F5B-, 6I3B-, 6I5B-
Region/Country: Brazil
Approval Agency: TÜV
Category: zone 2
Protection: Ex ecExplosion ProtectionPortuguese -
T-MASS F, T-MASS I
Product Code: 6F3B-, 6F5B-, 6I3B-, 6I5B-
Region/Country: Europe (ATEX)
Approval Agency: SIRA
Protection: [Ex ia], Ex tb, Ex ia tb, Ex db eb ia, Ex dbExplosion ProtectionEnglish -
T-MASS F, T-MASS I
Product Code: 6F3B-, 6F5B-, 6I3B-, 6I5B-
Region/Country: Brazil
Approval Agency: TÜV
Category: zone 21, zone 0,1
Protection: Ex ec, Ex db eb, Ex db, Ex tbExplosion ProtectionPortuguese -
T-MASS F, T-MASS I
Product Code: 6F3B-, 6I3B-
Region/Country: Japan
Approval Agency: CMLExplosion ProtectionJapanese -
T-MASS F, T-MASS I
Product Code: 6F3B-, 6F5B-, 6I3B-, 6I5B-
Region/Country: International (IECEx)
Approval Agency: CSA
Protection: [Ex ia], Ex ia, Ex tb, Ex ec, Ex db eb, Ex dbExplosion ProtectionEnglish
Accessories / Spare parts
-
-
Nr 31 Order code 71323007
Kit power supply, 100-230VAC, Ex
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing, electronic compartment.
-
Nr 31 Order code 71323008
Kit power supply, 24VDC, Ex
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing, electronic compartment.
-
Nr 31 Order code 71323009
Kit pow.supply,100-230VAC/24VDC, Non-haz
Usage: Promag/Promass/Prosonic Flow/ t-mass 300/500 digital, Non-haz, Zone 2, transmitter housing, electronic compartment.
-
-
-
Nr 33 Order code XPD0052-
ISEM electr.mod., t-mass 300/500 digital
Usage: t-mass 300/500 digital. Valid for approvals acc. feature 010. ISEM module V305-02.
-
-
-
Nr 39 Order code 71185788
Kit T-DAT, 100/300/400/500/500 digital
Usage: Promag/Promass 100/300/500, 500 digital, Prosonic Flow E 100, Prosonic Flow/t-mass 300, 500 digital, Promag 400(C). (C) = generation index C.
-
-
-
Nr 33 Order code XPD0053-
ISEM electr.mod., t-mass 300
Usage: t-mass 300 Valid for approvals acc. feature 010. ISEM module V305-01.
-
-
-
Nr 37 Order code 71323010
Kit module cartridge, 300/500, Ex
Usage: transmitter housing, electronic compartment. Consists of: module cartridge incl. interconnection board.
-
-
-
Nr 34 Order code XPD0037-
-
-
-
Nr 37 Order code 71323011
Kit module cartridge, 300, Non-haz
Usage: transmitter housing, electronic compartment. Consists of: module cartridge incl. interconnection board.
-
-
-
Nr 46 Order code 71323005
Kit ISEM ribbon cable, 300/500
Usage: Promag/Promass 300/500, t-mass 300, transmitter housing.
-
-
-
Nr 35 Order code XPD0038-
-
-
-
Nr 45 Order code 71323073
Kit conn.terminal option A, 300, Non-haz
Usage: transmitter housing Alu/hygienic, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol.
-
-
-
Nr 50 Order code XPD0031-
-
-
-
Nr 45 Order code 71327818
Kit conn.terminal option C, 300, Non-haz
Usage: transmitter housing Alu/hygienic, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol.
-
Nr 45 Order code 71323075
Kit conn.terminal option A, 300/500, Ex
Usage: transmitter housing Alu/cast, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus. Consists of: 2x connection terminal 2-Pol., 1x connection terminal 4-Pol.
-
Nr 45 Order code 71327819
Kit conn.terminal option C, 300/500, Ex
Usage: transmitter housing Alu/cast, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 2x connection terminal 2-Pol., 1x connection terminal 4-Pol.
-
-
-
Nr 49 Order code 71323079
Kit terminal, transm.,remote display,300
Usage: transmitter housing Alu/cast, connection compartment with remote display DKX001. Consists of: 1x connection terminal 4-Pol.
-
-
-
Nr 20 Order code 71323016
Kit cover, sight glass, Alu,Non-haz/Exde
Usage: Promag/Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Non-haz. Promag/Promass 300/500, transmitter housing Alu, Ex. Consists of: cover sight glass Alu, O-Ring 110.7x3.53 HNBR.
-
Nr 20 Order code 71323017
Kit cover,glass, Alu, -50oC,Non-haz/Exde
Usage: Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Non-haz. Promag 500, Promass 300/500, transmitter housing Alu, Ex. Consists of: cover Alu, sight glass, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 21 Order code 71323018
Kit cover, blind, Alu, Non-haz/Exde
Usage: Promag/Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Non-haz. Promag/Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 110,7x3,53 HNBR.
-
Nr 21 Order code 71323019
Kit cover, blind, Alu,-50oC,Non-haz/Exde
Usage: Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Non-haz. Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 20 Order code 71323020
Kit cover, sight glass, Alu, Exd
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu, Ex. Consists of: cover Alu, sight glass, O-Ring 110.7x3.53 HNBR.
-
Nr 20 Order code 71323021
Kit cover, sight glass, Alu, -50oC, Exd
Usage: Promag 500, Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu, Ex. Consists of: cover Alu, sight glass, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 21 Order code 71323022
Kit cover, blind, Alu, Exd
Usage: Promag/Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 110,7x3,53 HNBR.
-
Nr 21 Order code 71323023
Kit cover, blind, Alu, -50oC, Exd
Usage: Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 70 Order code 71323026
Kit cover gasket, sight glass/blind
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu/cast. Consists of: 10x O-Ring 110.7x3.53 HNBR.
-
Nr 70 Order code 71323027
Kit cover gasket,sight glass/blind,-50oC
Usage: Promag 500, Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu/cast, Consists of: O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 22 Order code 71323028
Kit cover, electr.compart., Alu, Non-haz
Usage: Promag/Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Non-haz. Consists of: cover Alu, O-Ring 117,1x3,53 HNBR.
-
Nr 22 Order code 71323029
Kit cover,electronic, Alu,- 50oC,Non-haz
Usage: Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Non-haz. Consists of: cover Alu, O-Ring 117,1x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 74 Order code 71323030
Kit cover gasket,electr.compart.,Non-haz
Usage: Promag/Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Non-haz. Consists of: 10x O-Ring 117,1x3,53 HNBR.
-
Nr 74 Order code 71323031
Kit cover gasket,electr., -50oC, Non-haz
Usage: Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Non-haz. Consists of: O-Ring 117,1x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 22 Order code 71323032
Kit cover, electronic compart., Alu, Ex
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 120,2x3,53 HNBR.
-
Nr 22 Order code 71323033
Kit cover, electr.compart., Alu,-50oC,Ex
Usage: Promag 500, Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 74 Order code 71323036
Kit cover gasket, electronic compart.,Ex
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu/cast, Ex. Consists of: 10x O-Ring 120,2x3,53 HNBR.
-
Nr 74 Order code 71323037
Kit cover gasket,elect.compart.,-50oC,Ex
Usage: Promag 500, Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu/cast, Ex. Consists of: O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 28 Order code 71323044
Kit cover, remote display, Alu
Usage: Remote display DKX001, housing Alu. Consists of: cover Alu, O-Ring 88,50x3,53 HNBR.
-
Nr 28 Order code 71323045
Kit cover, remote display, Alu, -50oC
Usage: Remote display DKX001, housing Alu. Consists of: cover Alu, O-Ring 88,50x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 76 Order code 71323048
Kit cover gasket, remote display
Usage: Remote display DKX001, housing Alu/cast. Consists of: 10x O-Ring 88,50x3,53 HNBR.
-
Nr 76 Order code 71323049
Kit cover gasket, remote display, -50oC
Usage: Remote display DKX001, housing Alu/cast. Consists of: O-Ring 88,50x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 71 Order code 71323071
Kit interface gaskets, 300/500
Usage: Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing/sensor or transmitter housing/wall mount. Consists of: 5x O-Ring 88,50x3,53 HNBR for interface.
-
Nr 71 Order code 71323072
Kit interface gaskets, 300/500, -50oC
Usage: Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing/sensor or transmitter housing/wall mount. Consists of: O-Ring 88,50x3,53 FVMQ for interface, -50oC/-58oF.
-
-
-
Nr 11 Order code 71368488
Kit protective cover optionA,300,Non-haz
Usage: transmitter housing Alu/hygienic, connection compartment. Option A = HART, PROFIBUS PA, PROFIBUS DP, Modbus RS485, FOUNDATION Fieldbus. Consists of: Connection compartment protective cover, display carrier, 2x screw M4x10.
-
Nr 11 Order code 71323081
Kit protective cover option A,300/500,Ex
Usage: transmitter housing Alu/cast, connection compartment. Option A = HART, PROFIBUS PA, PROFIBUS DP, Modbus RS485, FOUNDATION Fieldbus. Consists of: Connection compartment protective cover, display carrier, 2x screw M4x10.
-
-
-
Nr 87 Order code 71343505
Kit weather protection cover, 300/500
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing. Consists of: weather protection cover 4404, installation material.
-
-
-
Order code 71351317
Kit wireless antenna extended range
Consists of: Connection cable in the transmitter, Ex cable entry for antenna, 1.5m cable, antenna, angle with union nut.
-
Order code 6X3BXX-
-
Order code DKX001-
Remote Display DKX001
Remote display and operating module of Proline 300 For more installation flexibility and better readability. Delivery: Depends on the selection in the indvidual product structure.
-
Order code DKX002-
Connection Cable for Remote Display
Connection Cable for Remote Display DKX001 of Proline 300.
-
Order code XPRFID-
-