Specs at a glance
-
Max. measurement error
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm3 -
Measuring range
0 to 1000 kg/h (0 to 37 lb/min)
-
Medium temperature range
–50 to +205 °C (–58 to +401 °F)
-
Max. process pressure
PN 40, Class 300, 10K, 400 bar (5800 psi)
-
Wetted materials
Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L)
Field of application
Cubemass C is the ideal sensor for the measurement of smallest flow rates in skids, test rigs and industrial robotics. Neither high pressure nor alternating flow conditions compromise its accuracy. With its innovative remote transmitter Cubemass C 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology enables measurement reliability and compliant verification.
Measuring principle operates independently of physical fluid properties such as viscosity or density
Measuring accurately smallest quantities of liquids and gases
Device properties
Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄")
Process pressure up to 400 bar (5800 psi)
Medium temperature up to +205 °C (+401 °F)
Remote version with up to 4 I/Os
Backlit display with touch control and WLAN access
Standard cable between sensor and transmitter
Benefits
Space-saving installation – compact single-tube design
Fewer process measuring points – multivariable measurement (flow, density, temperature)
Suitable for skids – lightweight sensor
Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet
Reduced complexity and variety – freely configurable I/O functionality
Integrated verification – Heartbeat Technology
Videos
Predecessor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
-
Technical Information (TI)
Proline Cubemass C 500
English version - 08/2022
Coriolis flowmeter
EN 01/08/202201/06/202016/09/201915/07/201901/11/2018Language:
English
Version:
01/08/2022
File size:
11.4 MB
File name:
TI01281DEN_0822-00.pdf
-
-
-
Operating Instruction (BA)
Proline Cubemass C 500
English version - 08/2022
Coriolis flowmeter HART
EN 01/08/202201/06/202001/09/201902/10/201701/08/2016Language:
English
Version:
01/08/2022
File size:
9.8 MB
File name:
BA01527DEN_0522-00.pdf
-
-
-
Technical Information (TI)
Proline Cubemass C 500
Coriolis flowmeter
EN 01/08/202201/06/202016/09/201915/07/201901/11/2018Language:
English
Version:
01/08/2022
File size:
11.4 MB
File name:
TI01281DEN_0822-00.pdf
-
-
-
Operating Instruction (BA)
Proline Cubemass C 500 PROFIBUS PA
Coriolis flowmeter
EN 01/06/202001/11/201801/08/2016Language:
English
Version:
01/06/2020
File size:
8.4 MB
File name:
BA01549DEN_0320.pdf
-
-
-
Operating Instruction (BA)
Proline Cubemass C 500
Coriolis flowmeter
HARTEN 01/08/202201/06/202001/09/201902/10/201701/08/2016Language:
English
Version:
01/08/2022
File size:
9.8 MB
File name:
BA01527DEN_0522-00.pdf
-
-
-
Operating Instruction (BA)
Proline Cubemass C 500
Coriolis flowmeter
Modbus RS485EN 01/08/202201/06/202001/09/201902/10/201701/08/2016Language:
English
Version:
01/08/2022
File size:
9.2 MB
File name:
BA01538DEN_0522-00.pdf
-
-
-
Operating Instruction (BA)
Proline Cubemass C 500 PROFINET
Coriolis flowmeter
EN 01/06/202016/09/201915/07/201902/10/2017Language:
English
Version:
01/06/2020
File size:
11.8 MB
File name:
BA01759DEN_0420.pdf
-
-
-
Operating Instruction (BA)
Proline Cubemass C 500 PROFIBUS DP
Coriolis flowmeter
EN 01/06/202001/06/2018Language:
English
Version:
01/06/2020
File size:
8.2 MB
File name:
BA01871DEN_0220.pdf
-
-
-
Operating Instruction (BA)
Proline Cubemass C 500 FOUNDATION Fieldbus
Coriolis flowmeter
EN 01/06/202001/11/2016Language:
English
Version:
01/06/2020
File size:
8.1 MB
File name:
BA01560DEN_0220.pdf
-
-
-
Operating Instruction (BA)
Proline Cubemass C 500 Ethernet/IP
Coriolis flowmeter
EN 01/06/202002/10/2017Language:
English
Version:
01/06/2020
File size:
9.9 MB
File name:
BA01748DEN_0220.pdf
-
-
-
Operating Instruction (BA)
BA Proline Cubemass C 500
Coriolis flowmeter
PROFINET with Ethernet-APLEN 08/01/2024Language:
English
Version:
08/01/2024
File size:
9.6 MB
File name:
BA02123DEN_0122-00.pdf
-
-
-
Device Parameter (GP)
Proline Cubemass 500
Coriolis flowmeter
HARTEN 01/08/202201/09/201902/10/201702/08/2016Language:
English
Version:
01/08/2022
File size:
2.9 MB
File name:
GP01089DEN_0422-00.pdf
-