Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections Technical excellence Simplicity - F
- L
- E
- X
Fundamental selection
Meet your basic measurement needs
Technical excellence Simplicity - F
- L
- E
- X
Lean selection
Handle your core processes easily
Technical excellence Simplicity - F
- L
- E
- X
Extended selection
Optimize your processes with innovative technologies
Technical excellence Simplicity - F
- L
- E
- X
Xpert selection
Master your most challenging applications
Technical excellence Simplicity Variable
-
-
Measuring principle
Electromagnetic
-
Product headline
The sensor with degree of protection IP68 (Type 6P enclosure) and a modular electronic concept.
The specialist in the water and wastewater industry for the most demanding applications. -
Sensor features
Secure, reliable long‐term operation – robust and completely welded sensor. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
International drinking water approvals. Degree of protection IP68 (Type 6P enclosure). -
Transmitter features
Quality – designed for custody transfer; featuring worldwide recognized metrological approvals. Safe operation – display provides easily readable process information. Fully industry-compliant – IEC/EN/NAMUR.
2-line backlit display with push buttons. Device as compact or remote version. HART, PROFIBUS PA/DP. -
Nominal diameter range
DN 25...2000
1"...78" -
Max. measurement error
±0.5%
±0.2% (optional) -
Measuring range
0...110'000 m3/h
-
Max. process pressure
PN6...40
Cl 150...300
JIS 10...20K
AWWA Class D
AS 2129 Table E
AS 4087 PN16 -
Medium temperature range
-20...+80°C
(-4...+176°F) -
Ambient temperature range
-20...+60°C
-40...+60°C (optional) -
Degree of protection
IP 67 (NEMA 4x)
IP 68 (Nema 6P) -
Display/Operation
Two line display with backlit
Push button -
Outputs
4...20 mA
Pulse/Frequency
Status -
Inputs
Status
-
Digital communication
HART
PROFIBUS PA/DP -
Hazardous area approvals
ATEX, IECEx, NEPSI, FM, CSA
-
Product safety
CE, C-tick, EAC marking
-
Pressure approvals and certificates
PED, CRN
-
Hygienic approvals and certificates
Drinking water approvals: ACS, NSF 61, KTW/W270, WRAS BS6920