Specs at a glance
-
Process temperature
Standard:
-20 ... 100°C
Cleaning:
-20 ... 135°C for 1h
-4 ... 275F for 1h -
Process pressure / max. overpressure limit
Vacuum ... 16 bar
Vacuum ....232 psi
Field of application
The Liquipoint FTW23 is developed and built for the food industry and meets all international hygiene requirements. The device also fits perfectly for industrial applications in all industries. It is intended for use in applications in liquid media without build-up. The IO-Link capability allows easy parameter setting.
For use in storage tanks, mixing vessels and pipes. For water-based liquids; Ex works for media with dielectric constant > 20, with adjustment via IO-Link for media with dielectric constant > 1.5 discernible.
Process connections: Threads
Temperature: -20 to +100°C (-4 to +212°F), CIP/SIP to 135°C (275°F) for 1 hour
Pressure: -1 to 16bar abs (-14.5 to 232psi)
Hygienic certificates
Benefits
Easy installation thanks to compact design, even in tight conditions or where access is restricted
IO-Link reduces costs and complexity due to easy configuration of the devices via engineering tools
CIP and SIP cleanability ensured - up to protection class IP 69
Individual adjustment to each medium not necessary
LED display for on-site function check
Videos
-
Liquipoint FTW23 demonstration in different media
-
FTW23 part of a strong team for standard applications - Liquiphant, Liquipoint, Cerabar, Ceraphant
Fundamental selection
-
Simple products
- Easy to select, install and operate
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
Success stories
-
Measuring principle
Capacitive Liquid
-
Characteristic / Application
Compact point level switch for using in water based liquids
-
Specialities
CIP and SIP suitable
-
Supply / Communication
10…30 V DC
-
Ambient temperature
-20...70°C
-4... 158°F -
Process temperature
Standard:
-20 ... 100°C
Cleaning:
-20 ... 135°C for 1h
-4 ... 275F for 1h -
Process pressure / max. overpressure limit
Vacuum ... 16 bar
Vacuum ....232 psi -
Main wetted parts
Sensor: 316L
Sensor isolation: PEEK -
Process connection
Thread G1, G1/2, G3/4, M24
-
Communication
DC PNP
IO- Link -
Certificates / Approvals
CSA C/US
-
Design approvals
EN 10204-3.1
-
Hygienic approvals
3A, EHEDG
-
Options
Weld-in adapter,
Process adapter for hygienic process connections -
Application limits
Conductive foam is recognizes as a liquid
-
-
Technical Information (TI)
TI Liquipoint FTW23
English version - 07/2023
New version available in English
Capacitance point level measurement
EN 06/07/202330/10/201731/03/201630/10/201501/10/2015Language:
English
Version:
06/07/2023
File size:
835.7 KB
File name:
TI01202FEN_0623-00.pdf
-
-
-
Operating Instruction (BA)
Liquipoint FTW23 Operating Instructions Betriebsanleitung
English version - 10/2015
New version available in English
Point level switch for liquids in the food and beverage industry
EN 30/10/201524/06/2015Language:
English
Version:
30/10/2015
File size:
1.4 MB
File name:
BA01373FA2_0215.pdf
-
-
-
Technical Information (TI)
TI Weld-in adapter, process adapter and flanges
-
Technical Information (TI)
English version - 12/2024Level, pressure and temperature measurement
EN 06/12/202425/03/202415/09/202328/10/202130/07/2021Language:
English
Version:
06/12/2024
File size:
1.3 MB
File name:
TI00426FEN_2624.pdf
-
-
-
Technical Information (TI)
TI Liquipoint FTW23
-
Technical Information (TI)
English version - 07/2023Capacitance point level measurement
EN 06/07/202330/10/201731/03/201630/10/201501/10/2015Language:
English
Version:
06/07/2023
File size:
835.7 KB
File name:
TI01202FEN_0623-00.pdf
-
-
-
Operating Instruction (BA)
Liquipoint FTW23 Operating Instructions Betriebsanleitung
-
Operating Instruction (BA)
English version - 10/2015Point level switch for liquids in the food and beverage industry
EN 30/10/201524/06/2015Language:
English
Version:
30/10/2015
File size:
1.4 MB
File name:
BA01373FA2_0215.pdf
-
-
-
Operating Instruction (BA)
Liquipoint FTW23 IO-Link Operating Instructions
-
Operating Instruction (BA)
English version - 10/2017Point level switch for liquids
in the food and beverage industryEN 30/10/2017Language:
English
Version:
30/10/2017
File size:
1.4 MB
File name:
BA01792FEN_0117.pdf
-
-
-
Short Instruction (KA)
Liquipoint FTW23 IO-Link Brief Operating Instructions
-
Short Instruction (KA)
English version - 11/2018Point level switch for liquids
in the food and beverage industryEN 19/11/2018Language:
English
Version:
19/11/2018
File size:
1.3 MB
File name:
KA01401FEN_0118.pdf
-
-
-
Short Instruction (KA)
KA Liquipoint FTW23
-
Short Instruction (KA)
English version - 08/2022Point level switch for liquids
in the food and beverage industryEN 15/08/2022Language:
English
Version:
15/08/2022
File size:
335.7 KB
File name:
KA01593FEN_0122-00.pdf
-
-
-
Short Instruction (KA)
KA Liquipoint FTW23 IO-Link
-
Short Instruction (KA)
English version - 08/2022Point level switch for liquids
in the food and beverage industryEN 15/08/2022Language:
English
Version:
15/08/2022
File size:
342.8 KB
File name:
KA01592FEN_0122-00.pdf
-
-
-
ZE (Certificate)
Certificate of Compliance Liquipoint FTW23
-
ZE (Certificate)
English version - 02/2018ACTALIA -3/2015 (EHEDG)
EN 07/02/201815/02/201730/11/2015Language:
English
Version:
07/02/2018
File size:
1.9 MB
File name:
ZE01026FEN_0318.pdf
-
-
-
ZE (Certificate)
Herstellerbescheinigung/Declaration of Compliance Liquipoint FTW23
-
ZE (Certificate)
English version - 08/2018HE_00252_02.15
EN 20/08/2018Language:
English
Version:
20/08/2018
File size:
1.6 MB
File name:
ZE01052FA2_0118.pdf
-
-
-
Special Documentation (SD)
Application conditions for seals and plastics in the food sector Level measurement, pressure measurement Special Documentation
-
Special Documentation (SD)
English version - 07/2019Application conditions for seals and plastics in the food sector
EN 23/07/2019Language:
English
Version:
23/07/2019
File size:
97.6 KB
File name:
SD02430FEN_0119.pdf
-
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our privacy policy .