Specs at a glance
-
Process temperature
-50°C ... 180°C
(-58°F ... 356°F) -
Process pressure / max. overpressure limit
Vacuum ... 25 bar
(Vacuum ... 362 psi)
Field of application
Solicap FTI55 is a fully/partly insulated and robust rod probe for point level detection of fine-grained to coarse-grained bulk solids. It offers maximum reliability due to its active build-up compensation and is suited for a wide range of applications thanks to numerous certificates and approvals. Due to its robust construction, it can also be used to provide accurate measurements in applications with very high lateral loads up to 300Nm.
For applications with very high lateral loads up to 300Nm. Fieldgate and Solicap represent a solution for material provisioning and logistical optimization (inventory control)
Process connections: Flanges and threads
Measurement range: 200 to 4,000mm (4 to 157")
Temperature: -50 to +180°C (-58 to +356°F)
Pressure: -1 to +25bar (-14.5 to +363psi)
International explosion protection certificates, SIL
Benefits
Highest safety and reliability due to robust design for demanding process conditions
Cost savings thanks to easy and fast commissioning as calibration is performed at the press of a button
Universal application thanks to wide range of certificates and approvals
Two-stage overvoltage protection against static discharges from the silo
Active build-up compensation for bulk solids with caking tendency (under development)
Increased safety due to permanent automatic monitoring of electronics
Reduction in storage costs thanks to easy-to-shorten rod model (for partial insulation) and rope model (for partial and full insulation)
Videos
-
Capacitance point level detection with active build-up compensation
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Success stories
-
Measuring principle
Capacitive Solid
-
Characteristic / Application
Fully / partly isulated rod probe for small-grain / large-grain bulk solids
Simple calibration
Suitable for abrasive media
Very robust probe -
Specialities
Inactive length
Active build-up compensation
High lateral loading
Extremely robust probe -
Supply / Communication
19 ... 253V AC
10 ... 55V DC-PNP
19...253V AC bzw 10...55V DC
8/16mA, 11 ... 36V DC
PFM
3-wire -
Ambient temperature
-50°C ... 70°C
(-58°F ... 158°F) -
Process temperature
-50°C ... 180°C
(-58°F ... 356°F) -
Process pressure / max. overpressure limit
Vacuum ... 25 bar
(Vacuum ... 362 psi) -
Main wetted parts
PE, PPS, 316L, Steel
-
Process connection
Thread R1 1/2, NPT1 1/2
Flanges from DN50.../ASME 2".../JIS... -
Sensor length
0.2m ... 4m
(8" ... 157")
Inactive length: 0.1m ...1m
(2" ... 39") -
Communication
2- wire 19-253 VAC
DC PNP
Relais DPDT
PFM
3-wire
8/16 mA -
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, JPN Ex, NEPSI
-
Safety approvals
SIL
-
Design approvals
EN 10204-3.1
-
Components
PFM: FTC325, FTC625, FTC470Z, FTC471Z
3-wire: FTC325 -
Application limits
DK min 2
-
-
Technical Information (TI)
Solicap M FTI55, FTI56 Technical Information
English version - 10/2015
New version available in English
Point level switch for bulk solids
EN 26/10/201505/03/201014/11/200826/08/2006Language:
English
Version:
26/10/2015
File size:
1.4 MB
File name:
TI00418FEN_1315.pdf
-
-
-
Operating Instruction (BA)
Solicap M FTI55, FTI56 Operating Manual
English version - 10/2015
New version available in English
Capacitive point level switch
EN 26/10/201505/03/201014/11/200826/09/2006Language:
English
Version:
26/10/2015
File size:
1.9 MB
File name:
BA00300FEN_13.15.pdf
-
-
-
Technical Information (TI)
Solicap M FTI55, FTI56 Technical Information
-
Technical Information (TI)
English version - 10/2015Point level switch for bulk solids
EN 26/10/201505/03/201014/11/200826/08/2006Language:
English
Version:
26/10/2015
File size:
1.4 MB
File name:
TI00418FEN_1315.pdf
-
-
-
Technical Information (TI)
TI Solicap M FTI55
-
Technical Information (TI)
English version - 02/2025Capacitance
EN 14/02/202505/09/202425/09/2023Language:
English
Version:
14/02/2025
File size:
1.1 MB
File name:
TI01556FEN_0325-00.pdf
-
-
-
Operating Instruction (BA)
BA Solicap M FTI55
-
Operating Instruction (BA)
English version - 09/2024Capacitance
EN 05/09/202425/09/2023Language:
English
Version:
05/09/2024
File size:
2.5 MB
File name:
BA02033FEN_0224-00.pdf
-
-
-
Operating Instruction (BA)
Solicap M FTI55, FTI56 Operating Manual
-
Operating Instruction (BA)
English version - 10/2015Capacitive point level switch
EN 26/10/201505/03/201014/11/200826/09/2006Language:
English
Version:
26/10/2015
File size:
1.9 MB
File name:
BA00300FEN_13.15.pdf
-
-
-
Short Instruction (KA)
Solicap M FTI55
-
Short Instruction (KA)
English version - 09/2021Capacitance point level switch
EN 01/09/2021Language:
English
Version:
01/09/2021
File size:
700.2 KB
File name:
KA01485FEN_0120.pdf
-
-
-
Installation Instructions (EA)
Cover for housing T13 terminal compartment Installation instruction
-
Installation Instructions (EA)
English version - 02/2022Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
EN 24/02/202215/08/201409/08/2012Language:
English
Version:
24/02/2022
File size:
119 KB
File name:
EA01050FA2_0322.pdf
-
-
-
Installation Instructions (EA)
Cover for housing T13 electronic compartment Installation instruction
-
Installation Instructions (EA)
English version - 08/2014Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
EN 11/08/201409/08/2012Language:
English
Version:
11/08/2014
File size:
164.3 KB
File name:
EA01048FA2_0214.pdf
-
-
-
Installation Instructions (EA)
Cover for housing F13 Installation instruction
-
Installation Instructions (EA)
English version - 08/2014Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
EN 11/08/201409/08/2012Language:
English
Version:
11/08/2014
File size:
134.4 KB
File name:
EA01046FA2_0214.pdf
-
-
-
Installation Instructions (EA)
Cover for housing F27 Installation instruction
-
Installation Instructions (EA)
English version - 08/2014Liquihant M/S, Soliphant M, Liquicap M, Solicap M/S
EN 11/08/201416/01/201409/08/2012Language:
English
Version:
11/08/2014
File size:
136.4 KB
File name:
EA01047FA2_0314.pdf
-
-
-
Installation Instructions (EA)
Cover for housing T13 electronic compartment with sight glas Installation instruction
-
Installation Instructions (EA)
English version - 08/2012Liquicap M, Solicap M, Liquphant M/S/FailSafe, Soliphant M
EN 09/08/2012Language:
English
Version:
09/08/2012
File size:
158.7 KB
File name:
EA01049FA2_01.12.pdf
-
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories
Related products
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our privacy policy .