Specs at a glance
-
Accuracy
up to 0.5 mm
-
Process temperature
-40°C…150°C
(-40°F...302°F) -
Process pressure / max. overpressure limit
Vacuum ... 25 bar abs
-
Max. measurement distance
40 m (131 ft)
For calibration to regulatory standards:
30 m (98 ft) -
Main wetted parts
316L, PTFE
Field of application
Micropilot NMR84 is used for custody transfer and inventory control applications with NMi- and PTB-approvals. It meets the relevant requirements according to OIML R85 and API 3.1B. The NMR84 free space radar with drip-off planar antenna is specifically suited for stilling well applications. The superior drip-off antenna design with proven track record eliminates problems caused by condensation.
With planar antenna particularly suited for stilling well applications.
Process connections: Flanges
Temperature: -40 to +150°C (-40 to +302°F)
Pressure: Vacuum to +25bar (Vacuum to +362psi)
Maximum measuring range: 40m (131ft)
Accuracy: ±0.5mm (±0.02")
Transmitting frequency: 6GHz
International explosion protection and custody transfer certificates, overfill prevention WHG, SIL
Benefits
-
Hardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy) for high level of safety
-
Maximum reliability through accuracy up to ±0.5mm (±0.02")
-
Developed according to international metrology recommendations such as OIML R85 and API MPMS
-
Local and country-specific certifications like NMi or PTB for custody transfer applications
-
Simplified installation and trouble-free operations due to easy connection to major DCS systems via open protocols
-
Unique drip-off antenna design eliminates measurement error due to condensation build-up
Videos
Xpert selection
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Success stories
-
Measuring principle
Level radar
-
Characteristic / Application
Planar antenna, 6GHz: High precision measurement for for storage tanks up to 30 m (98ft)
-
Specialities
Custody transfer level measurement
-
Supply / Communication
85-264VAC
52-74VAC
19-64VDC -
Accuracy
up to 0.5 mm
-
Ambient temperature
Standard:
-40°C…60°C
(-40°F...140°F)
For calibration to regulatory
standards:
-25°C…55°C
(-13°F...131°F) -
Process temperature
-40°C…150°C
(-40°F...302°F) -
Process pressure / max. overpressure limit
Vacuum ... 25 bar abs
-
Main wetted parts
316L, PTFE
-
Process connection
Flange:
DN100/4"…DN300/12"
UNI-Flange:
DN150/6"…DN300/12" -
Max. measurement distance
40 m (131 ft)
For calibration to regulatory standards:
30 m (98 ft) -
Communication
Outputs:
Fieldbus: Modbus RS485, V1, WM550
HART, BPM and TRL/2 (via GE option)
Analog 4-20mA output (Exi/ Exd)
Relay output (Exd)
Inputs:
Analog 4-20mA input (Exi/ Exd)
2-, 3-, 4-wire RTD input
Discrete input (Exd, passive/ active) -
Certificates / Approvals
ATEX, FM, IEC Ex, EAC, JPN Ex, KC Ex,
INMETRO, NEPSI, UK Ex -
Safety approvals
Overfill protection WHG
SIL -
Design approvals
EN 10204-3.1
NACE MR0175, MR0103
AD2000 -
Metrological approvals and certificates
OIML, NMi, PTB
-
Options
Redundant fieldbus
Alu-coated or 316L housing
Weather protection cover -
Application limits
Maximum measuring range is
dependent on the tank form and/
or application
Strong condensate or build-up
formation
-
-
Technical Information (TI)
TI Micropilot NMR84
English version - 03/2024
New version available in English
Tank Gauging
EN 25/03/202415/09/202228/09/202101/06/202007/06/2018Language:
English
Version:
25/03/2024
File size:
2.2 MB
File name:
TI01253GEN_0723-00.pdf
-
-
-
Operating Instruction (BA)
BA Micropilot NMR84
English version - 11/2023
New version available in English
Tank Gauging
EN 01/11/202315/09/202204/11/202105/10/202013/07/2018Language:
English
Version:
01/11/2023
File size:
5 MB
File name:
BA01453GEN_0823-00.pdf
-
-
-
Technical Information (TI)
TI Micropilot NMR84
-
Technical Information (TI)
English version - 03/2024Tank Gauging
EN 25/03/202415/09/202228/09/202101/06/202007/06/2018Language:
English
Version:
25/03/2024
File size:
2.2 MB
File name:
TI01253GEN_0723-00.pdf
-
-
-
Operating Instruction (BA)
BA Micropilot NMR84
-
Operating Instruction (BA)
English version - 11/2023Tank Gauging
EN 01/11/202315/09/202204/11/202105/10/202013/07/2018Language:
English
Version:
01/11/2023
File size:
5 MB
File name:
BA01453GEN_0823-00.pdf
-
-
-
Device Parameter (GP)
GP Micropilot NMR84
-
Device Parameter (GP)
English version - 03/2024Tank Gauging
EN 25/03/202424/02/202229/06/201701/03/2016Language:
English
Version:
25/03/2024
File size:
3.5 MB
File name:
GP01071GEN_0524-00.pdf
-
-
-
Short Instruction (KA)
KA Micropilot NMR84
-
Short Instruction (KA)
English version - 03/2024Tank Gauging
EN 25/03/202404/11/202122/09/202019/11/201824/05/2017Language:
English
Version:
25/03/2024
File size:
1.9 MB
File name:
KA01197GEN_0623-00.pdf
-
-
-
Installation Instructions (EA)
SD card with holder Installation Instructions
-
Installation Instructions (EA)
English version - 09/2017Micropilot NMR8x; Proservo NMS8x; Tankside Monitor NRF81
EN 30/09/201730/11/2016Language:
English
Version:
30/09/2017
File size:
1 MB
File name:
EA01184GA2_0217.pdf
-
-
-
Installation Instructions (EA)
Antenna NMR84 Installation Instructions
-
Installation Instructions (EA)
English version - 08/2017Micropilot NMR84
EN 31/08/2017Language:
English
Version:
31/08/2017
File size:
422.2 KB
File name:
EA01222GA2_0117.pdf
-
-
-
Installation Instructions (EA)
Housing filter Installation Instructions
-
Installation Instructions (EA)
English version - 02/2018Micropilot, Proservo, Tankside Monitor
EN 28/02/201830/11/2016Language:
English
Version:
28/02/2018
File size:
404 KB
File name:
EA01183GA2_0218.pdf
-
-
-
Installation Instructions (EA)
Display set, display holder Installation Instructions
-
Installation Instructions (EA)
English version - 11/2016Micropilot NMR8x; Proservo NMS8x; Tankside Monitor NRF81
EN 30/11/2016Language:
English
Version:
30/11/2016
File size:
1.1 MB
File name:
EA01185GA2_0116.pdf
-
-
-
Installation Instructions (EA)
Terminal set Installation Instructions
-
Installation Instructions (EA)
English version - 11/2016Micropilot NMR8x; Proservo NMS8x; Tankside Monitor NRF81
EN 30/11/2016Language:
English
Version:
30/11/2016
File size:
1 MB
File name:
EA01186GA2_0116.pdf
-
-
-
Installation Instructions (EA)
Cover, cover clamp, O-ring Installation Instructions
-
Installation Instructions (EA)
English version - 12/2018Microwave Level Measurement
EN 14/12/201830/11/2016Language:
English
Version:
14/12/2018
File size:
900.5 KB
File name:
EA01176GA2_0218.pdf
-
-
Terminal set, I/O module, Push-in, TG
-
Terminals
Drawing numberOrder code3771324756 -
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our privacy policy .