Specs at a glance
-
Measuring range
0 to 2.5 mg/l PO4-P (blue method)
0.05 to 10 mg/l PO4-P (blue method)
0.05 to 10 mg/l with dilution function to maximum 2.5 to 500 mg/l PO4-P (blue method)
0.5 to 20 mg/l PO4-P (yellow method)
0.5 to 50 mg/l PO4-P (yellow method)
0.5 to 50 mg/l with dilution function to maximum 10 to 1000 mg/l PO4-P (yellow method) -
Process temperature
4 to 40 °C (39.2 to 104 °F)
-
Process pressure
At atmospheric pressure, < 0.2 bar
Field of application
Liquiline System CA80PH offers online orthophosphate measurement for precise dosing of precipitants in wastewater treatment. As all Liquiline System analyzers, it enables plug & play of up to 4 Memosens sensors - minimizing the installation effort. Automatic calibration and cleaning and the low consumption of reagents save you operating costs. Advanced diagnostics with remote access ensure process safety and support you in providing process documentation to the authorities.
Liquiline System CA80PH supports you in optimizing the cleaning capacity of wastewater treatment plants. It monitors and controls:
Precipitant dosing in aeration basins
Wastewater treatment plant outlets
In industrial applications, Liquiline System CA80PH is used for the monitoring of cooling water cycles.
Benefits
Fast commissioning and plug & play thanks to Memosens technology and user-friendly operation
Easy upgrade of functionality - even to a complete measuring station - simply by adding modules and connecting Memosens sensors
Advanced diagnostics with remote access for increased process safety
-
Reduced operating costs through automatic calibration and cleaning and long reagent shelf life with cooling module
Available with both standardized measuring methods covering all applications: Molybdenum blue method and Molybdate Vanadate yellow method
Videos
-
Orthophosphate concentration in a liquid can be measured using the colorimetric measuring principle. This video shows what it is about and how this measuring principle works.
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
Success stories
-
Measuring principle
Colorimetric
-
Characteristic
Process analyzer for orthophosphate in aqueous solutions
Comply with standard colorimetric measuring principle, molybdenum blue method, following DIN EN 1189 or molybdate vanadate method -
Size
Housing (open version):
793 x 530 x 417 mm
31.22 x 20.87 x 16.42 in
Housing (closed version):
793 x 530 x 463 mm
31.22 x 20.87 x 18.23 in
Housing with base:
1723 x 530 x 463 mm
67.83 x 20.87 x 18.23 in -
Design
Open design, cabinet and stand housing
High-Performance plastic ASA-PC, additional stand coated steel -
Process temperature
4 to 40 °C (39.2 to 104 °F)
-
Ambient temperature
5 to 40 °C (41 to 104 °F)
Outdoor version: - 20 to 40 °C (-4 to 104 °F) -
Process pressure
At atmospheric pressure, < 0.2 bar
-
Sample flow rate
Min. 5 ml/min (0.17 fl.oz/min)
-
Consistency of the sample
Suspended solids content
Turbitity < 50 NTU, aqueous, homogenized -
Application
Monitoring and optimization of the cleaning capacity of municipal and industrial waste water treatment plants
-
Power supply
100 to 120 VAC / 200 to 240 VAC ± 10%
24 VDC ± 10%
50 ± 1 or 60 ± 1,2 Hz -
Output / communication
2x 0/4 to 20 mA
Modbus RS485/TCP -
Input
1 or 2 measuring channel
1 to 4 digital sensor inputs for sensors with Memosens protocol (optional) -
Measuring range
0 to 2.5 mg/l PO4-P (blue method)
0.05 to 10 mg/l PO4-P (blue method)
0.05 to 10 mg/l with dilution function to maximum 2.5 to 500 mg/l PO4-P (blue method)
0.5 to 20 mg/l PO4-P (yellow method)
0.5 to 50 mg/l PO4-P (yellow method)
0.5 to 50 mg/l with dilution function to maximum 10 to 1000 mg/l PO4-P (yellow method) -
Consumables
Reagents and standard solutions CY80H as well as cleaner CY800 (blue method) are necessary for the operation
Regular maintenance is done with the parts of the maintenance kit CAV800
-
-
Technical Information (TI)
TI Liquiline System CA80PH
English version - 05/2024
New version available in English
Colorimetric analyzer for orthophosphate
EN 23/05/202430/11/202231/05/202114/02/202009/06/2017Language:
English
Version:
23/05/2024
File size:
4.3 MB
File name:
TI01219CEN_0724-00.pdf
-
-
-
Operating Instruction (BA)
BA Liquiline System CA80PH
English version - 05/2024
New version available in English
Colorimetric analyzer for orthophosphate (molybdate-vanadate method)
EN 23/05/202430/11/202231/05/202113/01/202009/06/2017Language:
English
Version:
23/05/2024
File size:
6.7 MB
File name:
BA01435CEN_0724-00.pdf
-
-
-
Technical Information (TI)
TI Liquiline System CA80PH
-
Technical Information (TI)
English version - 05/2024Colorimetric analyzer for orthophosphate
EN 23/05/202430/11/202231/05/202114/02/202009/06/2017Language:
English
Version:
23/05/2024
File size:
4.3 MB
File name:
TI01219CEN_0724-00.pdf
-
-
-
Operating Instruction (BA)
BA Liquiline System CA80PH
-
Operating Instruction (BA)
English version - 05/2024Colorimetric analyzer for orthophosphate (molybdate-vanadate method)
EN 23/05/202430/11/202231/05/202113/01/202009/06/2017Language:
English
Version:
23/05/2024
File size:
6.7 MB
File name:
BA01435CEN_0724-00.pdf
-
-
-
Operating Instruction (BA)
Memosens
-
Operating Instruction (BA)
English version - 05/2022Sensor inputs with Memosens protocol
EN 30/05/202228/02/2019Language:
English
Version:
30/05/2022
File size:
3.3 MB
File name:
BA01245CEN_0822-00.pdf
-
-
-
Operating Instruction (BA)
BA Liquiline System CA80PH
-
Operating Instruction (BA)
English version - 05/2024Colorimetric analyzer for orthophosphate ( blue method)
EN 23/05/202430/11/202231/05/202113/01/202009/06/2017Language:
English
Version:
23/05/2024
File size:
6.7 MB
File name:
BA01416CEN_0724-00.pdf
-
-
-
Short Instruction (KA)
Liquiline System CA80PH
-
Short Instruction (KA)
English version - 05/2021Colorimetric analyzer for orthophosphate
EN 31/05/202119/02/202006/10/201707/04/201701/02/2016Language:
English
Version:
31/05/2021
File size:
3.6 MB
File name:
KA01186CEN_0621.pdf
-
-
-
Installation Instructions (EA)
Kit for analyzer CA8x: Valve
-
Installation Instructions (EA)
English version - 05/2025This instruction applies to following spare part kit:
71218433 Kit CA8x: ValveEN 09/05/2025Language:
English
Version:
09/05/2025
File size:
2.1 MB
File name:
71231926 Anleitung Kit CA80 Ventil 2025-05_09-05-2025.pdf
-
-
-
Installation Instructions (EA)
Kit CM44x/CSXxx/CA80XX
-
Installation Instructions (EA)
English version - 11/2022Module 485MB or 485DP
For Ethernet configuration, PROFIBUS DP, Modbus RS485EN 28/11/2022Language:
English
Version:
28/11/2022
File size:
1.8 MB
File name:
EA01447CEN_0122-00.pdf
-
-
-
Installation Instructions (EA)
Kit manual for CAV800: Maintenance
-
Installation Instructions (EA)
English version - 05/2025Kits for analyzer CA80: Maintenance kit CAV800
EN 09/05/2025Language:
English
Version:
09/05/2025
File size:
1.9 MB
File name:
71223025 Anleitung Kits CAV800 Wartung 2025-05.pdf
-
-
-
Installation Instructions (EA)
Kits for analyzer CA80: Maintenance kit CAV800
-
Installation Instructions (EA)
English version - 05/2025Installation instruction for CAV800
Kits for single parameter analyzerEN 22/05/202511/03/2025Language:
English
Version:
22/05/2025
File size:
1.9 MB
File name:
71223025 Anleitung Kits CAV800 Wartung 2025-05.pdf
-
-
-
Installation Instructions (EA)
EA CA8x / CAT8xx
-
Installation Instructions (EA)
English version - 02/2025Hose connector
EN 13/02/2025Language:
English
Version:
13/02/2025
File size:
1.8 MB
File name:
EA01522CEN_0125-00.pdf
-
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories
Related products
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our privacy policy .