Specs at a glance
-
Spectral coverage
Base Model and Enclosure configuration:
150-4350 cm-1 (532 nm)
150-3425 cm-1 (785 nm)
200-2400 cm-1 (1000 nm)
Hybrid: 175-1890 cm-1 (785 nm)
Field of application
The Raman Rxn4 analyzer powered by Kaiser Raman technology is the optimal choice for manufacturing or process environments. Raman Rxn4 provides high-resolution performance for in situ, real-time measurement and control. It features unique self-monitoring, diagnostics, and self-calibration to ensure the validity of each measurement. Stackable in a standard 19" rack, the Raman Rxn4 saves valuable space on the production floor. It is also offered with an optional stainless steel NEMA 4X enclosure.
Chemical: reaction monitoring, blending, catalysis investigations
Polymer: polymerization reaction monitoring, extrusion monitoring, polymer blending
Pharmaceutical: API reaction monitoring, crystallization, polymorph
Biopharmaceutical: bioprocess monitoring and control, PAT/QbD applications, cell culture, fermentation, downstream operations, cGLP/cGMP compatible
Food & Beverage: Mapping of meats and fish, fermentation, offgas, volatiles
Oil & Gas: LNG, refining, energy measurements
Benefits
Robust, reliable, and highly accurate
Easy installation and minimal maintenance/downtime
24/7 inline, online, or at-line process measurement and monitoring
Unified internal construction enables straightforward model transfer to support redundant analyzer systems
Intuitive, fully embedded Raman RunTime control software via touchscreen or remote interface
Scale-up, scale-out, and cGMP/pilot-plant compatible
Suitable for outputs into hazardous area/classified environments
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
-
Technical Information (TI)
Raman Rxn4 Technical Information
System design and specifications for the Raman Rxn4 analyzer - powered by Kaiser Raman technology
Language:
English
Version:
21/11/2023
File size:
1.1 MB
File name:
TI01645CEN_0323.pdf
-
-
-
Operating Instruction (BA)
Raman RunTime Operating Instructions
Commissioning, operation, and maintenance details for Raman RunTime software
Language:
English
Version:
16/11/2023
File size:
6.7 MB
File name:
BA02180CEN_0423.pdf
-
-
-
Operating Instruction (BA)
Raman Rxn4 Operating Instructions
Commissioning, operation, and maintenance details for the Raman Rxn4 analyzer - powered by Kaiser Raman technology
Language:
English
Version:
21/11/2023
File size:
3.6 MB
File name:
BA02178CEN_0323.pdf
-
-
-
Short Instruction (KA)
Raman Rxn4 Brief Operating Instructions
Quick start guide for the Raman Rxn4 analyzer - powered by Kaiser Raman technology
Language:
English
Version:
21/11/2023
File size:
2.5 MB
File name:
KA01553CEN_0222.pdf
-
-
-
Installation Instructions (EA)
LNG analyzer performance verification kit Installation Instructions
Instructions for use of the LNG analyzer performance verification kit
Language:
English
Version:
30/03/2023
File size:
442.7 KB
File name:
EA01470CEN_0123.pdf
-
-
-
Ex Safety Instruction (XA)
Raman Rxn4 Safety Instructions
Hazardous area certifications and installation instructions for the Raman Rxn4 analyzer - powered by Kaiser Raman technology
Language:
English
Version:
29/11/2022
File size:
509 KB
File name:
XA02745CEN_0222.pdf
-
-
-
PU (Publication)
Raman analyzer application guide for the oil & gas and chemical industries - Composition analysis of gas streams and LNG
A guide to our Raman spectroscopy analyzer and probe portfolio, powered by Kaiser Raman technology, for composition analysis of gas streams and LNG (includes the Raman Rxn4 analyzer, the Raman Rxn5 analyzer, the Raman Rxn-30 probe, and Raman Rxn-41 probe) in the chemical industry and oil & gas industry.
Language:
English
Version:
08/12/2021
File size:
2.5 MB
File name:
PU01445CEN_0121.pdf
-
-
-
PU (Publication)
Kaiser Raman technology and Sartorius BioPAT Spectro® collaboration Q&A - Scalable, real-time bioprocess monitoring solutions
A Q&A about how our Raman spectroscopy analyzer systems (including the Raman Rxn2 analyzer, Raman Rxn4 analyzer, and Rxn-46 probe), powered by Kaiser Raman technology, integrates with the Sartorius BioPAT Spectro platform (Ambr and biostat STR) for high throughput and single use (SUB) bioprocessingin the biopharmaceutical life science industry.
Language:
English
Version:
08/12/2021
File size:
943.7 KB
File name:
PU01446CEN_0121.pdf
-
-
-
PU (Publication)
Advanced process and product control in fermentations - Raman spectroscopy for composition analysis in a lab or process
An overview of Raman spectroscopy analyzer systems (including the Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe, and Rxn-45 probe), powered by Kaiser Raman technology, for fermentation compositional analysis in a lab or process applicable to biotechnology in the food & beverage industry.
Language:
English
Version:
03/03/2022
File size:
603 KB
File name:
PU01457CEN_0122.pdf
-
-
-
PU (Publication)
Raman application guide for the life science industry - Trusted composition analysis for the life sciences
A guide to our Raman spectroscopy application notes for the Life Science industry (featuring the Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe, Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single use optic system / SUB, immersion optic, non-contact optic).
Language:
English
Version:
19/04/2022
File size:
1.1 MB
File name: