Specs at a glance
-
Measured Variables
Concentration
Moisture Dew Point
Cell Pressure
Cell Temperature -
Hazardous area approvals
CSA Class I, Division 1
CSA Class I, Division 2
CSA Class I, Zone 2
Field of application
Using the patented tunable diode laser spectroscopy (TDLAS) technology, the SS2000 single channel analyzer measures the concentration of H2O or CO2 in natural gas without coming into physical contact with the stream. The result is a sensor that does not suffer from contamination or drift due to vapor impurities such as glycol, methanol, or amines.
Natural gas quality measurements in production, storage, transportation, and distribution
Monitoring and controlling in the natural gas pipeline, processing plant, compressor station, gathering site, and distribution quality
Ideal for custody transfer measurements to ensure quality
Measurable ranges of up to 0-250 lb/mmscf (0-5275 ppm) H2O or up to 0-20% CO2
Benefits
Accurate, real-time H2O or CO2 measurements
Reliable in harsh environments and virtually maintenance-free
Fast and accurate with no wet-up or dry-down delays
No contamination or drift due to vapor impurities such as glycol, methanol, amines, hydrogen sulfide, or mercaptans
NIST-traceable calibration
Analog and serial outputs for remote monitoring
CSA certified for CSA Class 1, Division 2 or Class 1, Division 1
Xpert selection
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Measuring principle
TDLAS
-
Product Headline
Single channel gas analyzer for moisture (H2O) in the natural gas industry. The sensor measures gas using Tunable Laser Diode Absorption Spectroscopy (TDLAS) to determine the concentration of the gas without coming into physical contact with the stream.
-
Channels
1
-
Analyte and Measurement ranges
H2O (Moisture): 0-100 to 0-5000 ppmv
-
Measured Variables
Concentration
Moisture Dew Point
Cell Pressure
Cell Temperature -
Ambient Temperature range
-20 to 50°C (-4 to 122°F)
-
Operating Pressure range
Inlet Pressure: 140-350 kPa (20-50 psig)
Sample Cell: 700-1400 mbara -
Analyzer Wetted materials
316L Stainless Steel
FKM O-Rings
Glass -
Power supply
100-240 VAC, 50-60 Hz
OR
9-16 VDC or 18-32 VDC - optional
1 Amp maximum @ 120 VAC
1.6 Amp @ 24VDC, 3.2 Amp @ 12 VDC -
Communication
Analog Output: 1 or 2 4-20mA Isolated, 1200 ohms @ 24 VDC max load
Serial: RS232C
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Alarms: 2, General Fault and Concentration Alarms via Modbus and Analog Output(s) -
Housing materials
Electronics: 304 Stainless Steel (Class I Div 2)
Electronics: Cast Aluminum (Class I Div 1)
Sample System Panel: Anodized aluminum -
Hazardous area approvals
CSA Class I, Division 1
CSA Class I, Division 2
CSA Class I, Zone 2 -
Degree of protection
Type 3R (Class I Div 2)
Type 4 (Class I Div 1)
-
Measuring principle
TDLAS
-
Product Headline
Single channel gas analyzer for carbon dioxide (CO2) in the natural gas industry. The sensor measures gas using Tunable Laser Diode Absorption Spectroscopy (TDLAS) to determine the concentration of the gas without coming into physical contact with the stream.
-
Channels
1
-
Analyte and Measurement ranges
CO2 (Carbon Dioxide): 0-5% to 0-50%
-
Measured Variables
Concentration
Cell Pressure
Cell Temperature -
Ambient Temperature range
-20 to 50°C (-4 to 122°F)
-
Operating Pressure range
Inlet Pressure: 140-350 kPa (20-50 psig)
Sample Cell: 700-1400 mbara -
Analyzer Wetted materials
316L Stainless Steel
FKM O-Rings
Glass -
Power supply
100-240 VAC, 50-60 Hz
OR
9-16 VDC or 18-32 VDC - optional
1 Amp maximum @ 120 VAC
1.6 Amps @ 24VDC, 3.2 Amps @ 12 VDC -
Communication
Analog Output: 1 or 2 4-20mA Isolated, 1200 ohms @ 24 VDC max load
Serial: RS232C
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Alarms: 2, General Fault and Concentration Alarms via Modbus and Analog Output(s) -
Housing materials
Electronics: 304 Stainless Steel (Class I Div 2)
Electronics: Cast Aluminum (Class I Div 1)
Sample System Panel: Anodized aluminum -
Hazardous area approvals
CSA Class I, Division 1
CSA Class I, Division 2
CSA Class I, Zone 2 -
Degree of protection
Type 3R (Class I Div 2)
Type 4 (Class I Div 1)
Configure to download the CAD drawings of this product
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons