Specs at a glance
-
Accuracy
Standard: 0.05%
Platinum: up to 0.025% -
Process temperature
-40°C...150°C
(-40°F...302°F) -
Pressure measuring range
100mbar...40bar
(1.5psi...600psi) -
Process pressure / max. overpressure limit
60bar (900psi)
-
Main wetted parts
Ceraphire ceramic
Alloy C
316L
Monel
PVDF -
Max. measurement distance
400m (1312ft) H2O
-
Material process membrane
Ceramic
-
Measuring cell
100 mbar...40 bar
(1.5 psi...600 psi)
relative/ absolute
Field of application
The Cerabar PMC71 digital pressure transmitter with capacitive, oil-free ceramic measuring cell is typically used in the process and hygienic applications for pressure, level, volume or mass measurement in liquids and gases. It guarantees high degree of system safety thanks to vacuum-proof ceramic membrane with integrated breakage detection. Quick Setup with adjustable measuring range allows simple commissioning, reduces costs and saves time. SIL2/3 according to IEC 61508.
Two chamber aluminum or stainless steel (316L) housing.
Process connections: Threads, flanges or hygienic connections
Process temperature: -40 to +150°C (-40 to +302°F)
Measuring ranges: -1/0 up to to +40bar (+1.5 to +600psi)
Accuracy: ±0.05%, "Platinum" ±0.025%
International explosion protection certificates, overfill prevention WHG, SIL, hygienic approvals, marine approvals
Benefits
Best fit for vacuum applications and applications with corrosive and abrasive media
Process safety through membrane breakage detection
Overload-resistant high purity ceramic sensor (99.9% Al2O3)
HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
Highest safety due to gastight feedthrough with capabilities up to SIL2/3, certified to IEC 61508
Available with mounted manifolds: always fit, always tested for leaks
Videos
-
Pressure measuring principle
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
Measuring principle
Absolute and gauge pressure
-
Characteristic
Digital transmitter with capacitive sensor and ceramic membrane
Modular transmitter
Long term stability
Enhanced safety via self diagnostic functions
Secondary process barrier -
Supply voltage
4...20 mA HART
10,5...45V DC (Non Ex):
Ex ia: 10,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex) -
Reference Accuracy
Standard: 0.05%
Platinum: up to 0.025% -
Long term stability
0.05 % of URL/ year
0.08 % of URL/ 5 years
0.1 % of URL/ 10 years -
Process temperature
-20°C...150°C
(-4°F...257°F) -
Ambient temperature
-40°C...85°C
(-40°F...185°F) -
Measuring cell
100 mbar...40 bar
(1.5 psi...600 psi)
relative/ absolute -
Smallest calibratable span
5 mbar (0.075 psi)
-
Vacuum resistance
0 mbar abs.
-
Max. Turn down
100:1
-
Max. overpressure limit
60 bar (900 psi)
-
Process connection
Thread:
G1/2...G2, R1/2, MNPT1/2...MNPT2
Flange:
DN25...DN80,
ASME 1"...4",
JIS 10K -
Process connection hygienic
Tri-Clamp
DIN11851
Varivent N
SMS
DRD -
Material process membrane
Ceramic
-
Material gasket
Viton, EPDM, Chemraz, Kalrez, NBR
-
Fill fluid
none, dry measuring cell
-
Material housing
Die-cast aluminum,
AISI 316L -
Communication
4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus -
Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC, UK Ex
-
Design approvals
EN10204-3.1
-
Hygienic approvals
3A, EHEDG
-
Marine approvals
GL/ ABS
-
Drinking water approvals
NSF
-
Specialities
Diagnostic functions
-
Successor
PMC71B
-
Measuring principle
Absolute and gauge pressure
-
Characteristic / Application
Digital transmitter with capacitive sensor and ceramic membrane
Modular transmitter
Long term stability
Enhanced safety via self diagnostic functions
Secondary process barrier -
Specialities
diagnostic functionalities
different languages in software -
Supply / Communication
4...20mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC -
Accuracy
Standard: 0.05%
Platinum: up to 0.025% -
Long term stability
0,05% of URL/year
-
Ambient temperature
-40°C...85°C
(-40°F...185°F) -
Process temperature
-40°C...150°C
(-40°F...302°F) -
Process pressure / max. overpressure limit
60bar (900psi)
-
Pressure measuring range
100mbar...40bar
(1.5psi...600psi) -
Main wetted parts
Ceraphire ceramic
Alloy C
316L
Monel
PVDF -
Process connection
Threads
Flanges
Tri-Clamp ISO2852
Hygienic connections -
Max. measurement distance
400m (1312ft) H2O
-
Communication
4 ... 20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus -
Certificates / Approvals
ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC
-
Design approvals
EN 10204-3.1
-
Marine approval
GL/ ABS
-
Drinking water approvals
NSF
-
Options
HistoROM/M-Dat
4-line digital display
SS- or Aluminiumhousing
Separate housing -
Successor
PMC71B
-
Application limits
Measuring cell: ceramics
If pressurized, possibly
use differential pressure
measurement with two
pressure transmitters
(electronic dp). Observe
ratio head pressure :
hydrostatic pressure
-
-
Technical Information (TI)
TI Cerabar S PMC71, PMP71, PMP75
English version - 04/2024
New version available in English
Process pressure measurement 1-5 V DC, HART, PA, FF
EN 01/04/202413/01/202229/09/202001/04/202016/04/2019Language:
English
Version:
01/04/2024
File size:
3.5 MB
File name:
TI00383PEN_3624-00.pdf
-
-
-
Operating Instruction (BA)
Cerabar S PMC71, PMP71, PMP75 HART V02.30.zz Operating Instructions
English version - 08/2024
New version available in English
Pressure transmitter with ceramic and metal sensors
EN 01/08/202401/03/201810/12/201401/11/201407/05/2014Language:
English
Version:
01/08/2024
File size:
914.5 KB
File name:
BA00271PEN_2022.pdf
-
-
-
Technical Information (TI)
TI Weld-in adapter, process adapter and flanges
-
Technical Information (TI)
English version - 12/2024Level, pressure and temperature measurement
EN 06/12/202425/03/202415/09/202328/10/202130/07/2021Language:
English
Version:
06/12/2024
File size:
1.3 MB
File name:
TI00426FEN_2624.pdf
-
-
-
Technical Information (TI)
TI Cerabar S PMC71, PMP71, PMP75
-
Technical Information (TI)
English version - 04/2024Process pressure measurement
1-5 V DC, HART, PA, FFEN 01/04/202413/01/202229/09/202001/04/202016/04/2019Language:
English
Version:
01/04/2024
File size:
3.5 MB
File name:
TI00383PEN_3624-00.pdf
-
-
-
Operating Instruction (BA)
Cerabar S PMC71, PMP71, PMP75 HART V02.30.zz Operating Instructions
-
Operating Instruction (BA)
English version - 08/2024Pressure transmitter with ceramic and metal sensors
EN 01/08/202401/03/201810/12/201401/11/201407/05/2014Language:
English
Version:
01/08/2024
File size:
914.5 KB
File name:
BA00271PEN_2022.pdf
-
-
-
Operating Instruction (BA)
Cerabar S PMC71, PMP71, PMP75 FOUNDATION Fieldbus (V 04.00.zz) Operating Instructions
-
Operating Instruction (BA)
English version - 08/2024Pressure transmitter with ceramic and metal sensors
Overload-resistant and function-monitored;
Communication via
FOUNDA
TION FieldbusEN 01/08/202403/04/201710/12/201407/05/201430/04/2013Language:
English
Version:
01/08/2024
File size:
1.9 MB
File name:
BA00302PEN_1922-00.pdf
-
-
-
Operating Instruction (BA)
Cerabar S / Deltabar S / Deltapilot S, Description of device functions FOUNDATION Fieldbus V 04.00.zz
-
Operating Instruction (BA)
English version - 04/2017Cerabar S PMC71, PMP71, PMP75 Pressure transmitter
Deltabar S FMD77, FMD78, PMD75 Differential pressure
transmitter
Deltapilot S FMB70 Hydrostatic pressure transmitterEN 03/04/201710/12/201407/05/201430/04/201301/10/2011Language:
English
Version:
03/04/2017
File size:
6.3 MB
File name:
BA00303PEN_1716.pdf
-
-
-
Operating Instruction (BA)
Cerabar S PMC71, PMP71, PMP75 PROFIBUS PA (V 04.01.zz) Operating Instructions
-
Operating Instruction (BA)
English version - 08/2024Pressure transmitter with ceramic and metal sensors
Overload-resistant and function-monitored;
Communication via
PROFIB
USPAEN 01/08/202403/04/201710/12/201407/05/201407/08/2013Language:
English
Version:
01/08/2024
File size:
1.4 MB
File name:
BA00295PEN_1922-00.pdf
-
-
-
Operating Instruction (BA)
Cerabar S /Deltabar S /Deltapilot S Description of device functions PROFIBUS PA V04.01.zz
-
Operating Instruction (BA)
English version - 04/2017Cerabar S PMC71, PMP71, PMP75 Pressure transmitter
Deltabar S FMD77, FMD78, PMD75 Differential pressure
transmitter
Deltapilot S FMB70 Hydrostatic pressure transmitterEN 03/04/201710/12/201407/08/201301/10/201101/05/2010Language:
English
Version:
03/04/2017
File size:
4.8 MB
File name:
BA00296PEN_1616.pdf
-
-
-
Operating Instruction (BA)
Cerabar S Operating Instructions HART, Software version 7.1
-
Operating Instruction (BA)
English version - 01/2004Cerabar S PMC631, PMC731, PMP635, PMP731, Pressure transmitter
EN 01/01/200401/03/200301/04/1999Language:
English
Version:
01/01/2004
File size:
1.9 MB
File name:
BA187PEN.pdf
-
-
-
Operating Instruction (BA)
Cerabar S / Deltabar S / Deltapilot S HART V02.30.zz Description of Instrument Functions
-
Operating Instruction (BA)
English version - 03/2018Cerabar S PMC71, PMP71, PMP75 Pressure transmitter
Deltabar S FMD77, FMD78, PMD75 Differential pressure transmitter
Deltapilot S FMB70 Hydrostatic pressure transmitterEN 01/03/201810/12/201401/11/201407/05/201417/01/2013Language:
English
Version:
01/03/2018
File size:
4.8 MB
File name:
BA00274PEN_1816.pdf
-
-
-
Short Instruction (KA)
Cerabar S PMC71, PMP71, PMP75
-
Short Instruction (KA)
English version - 06/2022Process pressure measurement
EN 30/06/202203/04/201710/12/201407/05/201430/04/2013Language:
English
Version:
30/06/2022
File size:
1.2 MB
File name:
KA01025PEN_1922-00.pdf
-
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories
Related products
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our privacy policy .