Title

Try searching by key words, order- or product code or serial number e.g. “CM442” or “Technical information”
Enter at least 2 characters to start the search.

Media preparation

Explore measurement points and instrument selection across the media preparation process

F T F T T F T LS A Cond A pH T LS コンポーネントA WFI コンポーネントB J - 培地生成 Komponente A WFI Komponente B J - Medienherstellung Component A WFI Component B J - Media preparation
Flow Component A
Temperature in feedline A
Flow Component B
Temperature in feedline B
Temperature in feedline WFI
WFI supply
Media temperature
Maximum tank level
Conductivity
Media pH
Temperature in outlet line
Empty pipe detection
Measuring point Product Alternatives
Flow measurement in: Flow Component A

Endress+Hauser offers a suite of analytical instruments ideal for this stage.

Alternatives:

General Requirements:

  • Cleanability (CIP/SIP), no dead legs
  • Fully self-drainable in horizontal installations
  • Design according to ASME BPE standard
  • High reproducibility over a large flow range
  • Small quantities – dosing and batching

Technical requirements:

  • Measuring task: Liquids
  • Process pressure: 0 to 3 bar (0 to 43.5 psi)
  • Process temperature: 5 to 50°C (41 to 120°F)
  • CIP/SIP: 130°C (266°F)
  • Density: 0.8 to 1.25 g/cm³
Temperature measurement in: Temperature in feedline A

Endress+Hauser offers a suite of analytical instruments ideal for this stage.

Alternatives:

General Requirements:

  • Cleanability, no dead legs
  • Installation in thermowell
  • High accuracy and repeatability
  • Easy and accurate calibration in closed system
  • Short immersion length for small pipe installation
  • Design according to ASME BPE standard

Technical requirements:

  • Measuring task: Thermometer
  • Process pressure: 0 to 3 bar (0 to 43.5 psi)
  • Process temperature: 5 to 50°C (41 to 120°F)
  • CIP/SIP: 130°C (266°F)
  • Density: 0.8 to 1.25 g/cm³
Flow measurement in: Flow Component B

Endress+Hauser offers a suite of analytical instruments ideal for this stage.

Alternatives:

General Requirements:

  • Cleanability (CIP/SIP), no dead legs
  • Fully self-drainable in horizontal installations
  • Design according to ASME BPE standard
  • High reproducibility over a large flow range
  • Small quantities – dosing and batching

Technical requirements:

  • Measuring task: Liquids
  • Process pressure: 0 to 3 bar (0 to 43.5 psi)
  • Process temperature: 5 to 50°C (41 to 120°F)
  • CIP/SIP: 130°C (266°F)
  • Density: 0.8 to 1.25 g/cm³
Temperature measurement in: Temperature in feedline B

Endress+Hauser offers a suite of analytical instruments ideal for this stage.

Alternatives:

General Requirements:

  • Cleanability, no dead legs
  • Installation in thermowell
  • High accuracy and repeatability
  • Easy and accurate calibration in closed system
  • Short immersion length for small pipe installation
  • Design according to ASME BPE standard

Technical requirements:

  • Measuring task: Thermometer
  • Process pressure: 0 to 3 bar (0 to 43.5 psi)
  • Process temperature: 5 to 50°C (41 to 120°F)
  • CIP/SIP: 130°C (266°F)
  • Density: 0.8 to 1.25 g/cm³
Temperature measurement in: Temperature in feedline WFI

Endress+Hauser offers a suite of analytical instruments ideal for this stage.

Alternatives:

General Requirements:

  • Cleanability, no dead legs
  • Installation in thermowell
  • High accuracy and repeatability
  • Easy and accurate calibration in closed system
  • Short immersion length for small pipe installation
  • Design according to ASME BPE standard

Technical requirements:

  • Measuring task: Thermometer
  • Process pressure: 0 to 3 bar (0 to 43.5 psi)
  • Process temperature: 5 to 50°C (41 to 120°F)
  • CIP/SIP: 130°C (266°F)
  • Density: 0.8 to 1.25 g/cm³
Flow measurement in: WFI supply

Endress+Hauser offers a suite of analytical instruments ideal for this stage.

Alternatives:

General Requirements:

  • Cleanability (CIP/SIP), no dead legs
  • Fully self-drainable in horizontal installations
  • Design according to ASME BPE standard
  • High reproducibility over a large flow range
  • Non-conductive fluid

Technical requirements:

  • Measuring task: Liquids
  • Process pressure: 0 to 3 bar (0 to 43.5 psi)
  • Process temperature: 5 to 50°C (41 to 120°F)
  • CIP/SIP: 130°C (266°F)
  • Density: 0.8 to 1.25 g/cm³
Temperature measurement in: Media temperature

Endress+Hauser offers a suite of analytical instruments ideal for this stage.

Alternatives:

General Requirements:

  • Cleanability, no dead legs
  • Installation in thermowell
  • High accuracy and repeatability
  • Easy and accurate calibration in closed system
  • Design according to ASME BPE standard

Technical requirements:

  • Measuring task: Thermometer
  • Process pressure: 0 to 3 bar (0 to 43.5 psi)
  • Process temperature: 5 to 50°C (41 to 120°F)
  • CIP/SIP: 130°C (266°F)
  • Density: 0.8 to 1.25 g/cm³
Level measurement in: Maximum tank level

Endress+Hauser offers a suite of analytical instruments ideal for this stage.

Alternatives:

General Requirements:

  • Cleanability (CIP/SIP), no dead legs
  • Safe functionality
  • Universal use for all kinds of media
  • Low hysteresis
  • Design according to ASME BPE standard

Technical requirements:

  • Measuring task: Point Level / Liquids
  • Process pressure: 0 to 3 bar (0 to 43.5 psi)
  • Process temperature: 5 to 50°C (41 to 120°F)
  • CIP/SIP: 130°C (266°F)
  • Density: 0.8 to 1.25 g/cm³
Analysis measurement in: Conductivity

Endress+Hauser offers a suite of analytical instruments ideal for this stage.

Alternatives:

General Requirements:

  • High accuracy
  • Wide measurement range
  • Suitable for CIP/SIP
  • Fast response time
  • Design according to ASME BPE standard

Technical requirements:

  • Measuring task: Conductivity
  • Process pressure: 0 to 3 bar (0 to 43.5 psi)
  • Process temperature: 5 to 50°C (41 to 120°F)
  • CIP/SIP: 130°C (266°F)
  • Density: 0.8 to 1.25 g/cm³
Analysis measurement in: Media pH

Endress+Hauser offers a suite of analytical instruments ideal for this stage.

Alternatives:

General Requirements:

  • High accuracy
  • Suitable for CIP/SIP and autoclaves
  • Long-term stability
  • Easy and accurate calibration
  • Design according to ASME BPE standard

Technical requirements:

  • Measuring task: pH
  • Process pressure: 0 to 3 bar (0 to 43.5 psi)
  • Process temperature: 5 to 50°C (41 to 120°F)
  • CIP/SIP: 130°C (266°F)
  • Density: 0.8 to 1.25 g/cm³
Temperature measurement in: Temperature in outlet line

Endress+Hauser offers a suite of analytical instruments ideal for this stage.

Alternatives:

General Requirements:

  • Cleanability, no dead legs
  • Installation in thermowell
  • High accuracy and repeatability
  • Easy and accurate calibration in closed system
  • Short immersion length for small pipe installation
  • Design according to ASME BPE standard

Technical requirements:

  • Measuring task: Thermometer
  • Process pressure: 0 to 3 bar (0 to 43.5 psi)
  • Process temperature: 5 to 50°C (41 to 120°F)
  • CIP/SIP: 130°C (266°F)
  • Density: 0.8 to 1.25 g/cm³
Level measurement in: Empty pipe detection

Endress+Hauser offers a suite of analytical instruments ideal for this stage.

Alternatives:

General Requirements:

  • Cleanability, no dead legs
  • Small pipe mounting
  • Design according to ASME BPE standard

Technical requirements:

  • Measuring task: Point Level / Liquids
  • Process pressure: 0 to 3 bar (0 to 43.5 psi)
  • Process temperature: 5 to 50°C (41 to 120°F)
  • CIP/SIP: 130°C (266°F)
  • Density: 0.8 to 1.25 g/cm³
Cleanroom operator inspecting stainless steel processing equipment in a biopharmaceutical production

Key instrumentation challenges in the media preparation process

Media preparation is a critical upstream operation where instrumentation must ensure accurate formulation, reproducible batch quality, and GMP-compliant process control. Engineers need reliable measurement of flow, conductivity, pH, temperature, and level while managing challenges such as changing media compositions, sterilization cycles, data integrity requirements, and the need for real-time process visibility. Inaccurate or delayed measurements can lead to batch variability, process deviations, increased manual intervention and costly rework.

  • Composition verification and dosing accuracy: Achieving precise control of ingredient addition and validating final media composition through reliable flow, conductivity, and analytical measurements.
  • Sterile measurement points: Integrating sensors into hygienic systems without creating dead legs, contamination risks, or cleanability issues during CIP/SIP cycles.
  • Measurement stability under process variability: Maintaining accurate readings despite changes in temperature, concentration, mixing dynamics, and fluid properties throughout preparation and transfer.
  • Sensor reliability and calibration management: Preventing drift, fouling, and calibration deviations that can compromise media quality, batch release, and GMP documentation.
  • Data integrity and batch traceability: Ensuring secure, audit-ready capture of critical process data with complete traceability from raw material addition through final media release.
Portfolio highlights

Explore our innovations for your media preparation process

/
FAQ

Frequent questions about the media preparation process