Radar measurement
Micropilot FMR60
The standard sensor for highest demands in liquid level measurement with 80GHz technology
Micropilot FMR60 is the first 80GHz radar developed according to the international functional safety directive IEC 61508. The free space radar offers maximum reliability due to the drip-off antenna, improved algorithms and small beam angle. It is used for continuous non-contact level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors. It also possesses the smart sensor functionality Heartbeat Technology.
- F
- L
- E
- X
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Accuracy
+/- 1 mm (0.04 in)
-
Process temperature
-40…+130 °C
(-40…+266 °F) -
Process pressure absolute / max. overpressure limit
Vacuum …16 bar
(Vacuum … 232 psi) -
Max. measurement distance
50 m (164 ft)
-
Main wetted parts
PTFE antenna
PP or 316L process connections
-
Quick selection
Individual configuration
-
Benefits
-
Hardware and software developed according to IEC 61508 up to SIL3 in homogeneous redundancy
-
Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle
-
HistoROM data management concept for fast and easy commissioning...
-
-
Field of application
80GHz drip-off antenna suited for free space applications up to 50m and offers high beam focusing for vessels with many internal fittings.
Process connections: Threads or flanges
Temperature: –40 to +130°C (–40 to +266°F)
Pressure: –1 to +16bar (–14.5...
Documents / Manuals / Software
-
Micropilot FMR60
Free space radar
Technical Information (TI) -
Micropilot FMR60
HART
Operating Instructions
Free space radar
Operating Instruction (BA) -
Micropilot FMR6x
HART
Description of Device Parameters
Free-space radar
Device Parameter (GP) -
Micropilot FMR60
HART
Brief Operating Instructions
Free space radar
Short Instruction (KA)04/18English -
Main electronics module
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x
Installation Instructions (EA) -
Set housing security clamp
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Installation Instructions (EA) -
M12 connector, IP66/68 NEMA4X/6P, ProToF
Installation Instructions
Levelflex FMP5x
Micropilot FMR5x, FMR6xInstallation Instructions (EA) -
Housing GT18, GT19, GT20
Levelflex, Micropilot
Installation Instructions (EA) -
Transmitter electronics FHX50
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Installation Instructions (EA) -
Sealing set
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200, Remote display FHX50Installation Instructions (EA) -
Cover
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200, Remote display FHX50Installation Instructions (EA) -
Housing filter
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Installation Instructions (EA) -
Replacing the display module
Installation Instructions
Promag 200, Promass 200, Prosonic Flow 200, Prowirl 200, t-mass 150,
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x, Remote dis
play FHX50Installation Instructions (EA) -
Terminal set
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x, Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Installation Instructions (EA) -
I/O module
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Installation Instructions (EA) -
Antenna assembly
Installation Instructions
Micropilot FMR60, FMR62, FMR67
Installation Instructions (EA) -
Micropilot FMR60, FMR62, FMR67
4-20 mA HART
Ex ia/db [ia Ga] IIC T6...T1 Ga/Gb
Ex ta/tb IIIC T85°C Da/DbEx Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
ATEX:
II 1/2 G Ex ia IIC T6...T1 Ga/Gb
II 1/2 D Ex ia IIIC T85°C Da/Db
IECEx:
Ex ia IIC T6...T1 Ga/Gb
Ex ia IIIC T85°C Da/Db
Safety Instructions
Microwave Level Measurement
Ex Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
4-20 mA HART
Ga/Gb Ex ia/db [ia Ga] IIC T6...T3 XEx Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
4-20 mA HART
Ex ia/db [ia Ga] IIC T6...T1 Ga/GbEx Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
4-20 mA HART
Ex ia/db [ia Ga] IIC T6...T1 Ga/GbEx Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
ATEX:
II 1/2 G Ex ia/db [ia Ga] IIC T6...T1 Ga/Gb
II 1/2 D Ex ta/tb IIIC T85°C Da/Db
IECEx:
Exia/db [ia Ga] IIC T6...T1 Ga/Gb
Ex ta/tb IIIC T85°C Da/Db
Safety Instructions
Microwave Level Measurement
Ex Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
Control Drawing IS
Safety Instructions
Microwave Level Measurement
Ex Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
ATEX:
II 1/2 G Ex ia/db [ia Ga] IIC T6...T1 Ga/Gb
IECEx:
Ex ia/db [ia Ga] IIC T6...T1 Ga/Gb
Safety Instructions
Microwave Level Measurement
Ex Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
Control Drawing XP/DIP
Safety Instructions
Microwave Level Measurement
Ex Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
4-20 mA HART
Ex ia IIC T6...T1 Ga/Gb
Ex ia IIIC T85°C Da/DbEx Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
ATEX:
II 1 G Ex ia IIC T6...T1 Ga
II 1/2 G Ex ia IIC T6...T1 Ga/Gb
IECEx:
Ex ia IIC T6...T1Ga
Ex ia IIC T6...T1 Ga/Gb
Safety Instructions
Microwave Level Measurement
Ex Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
NEPSI:
Ex ia/d [ia Ga] IIC T6 Ga/Gb
Safety Instructions
Microwave Level Measurement
Ex Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
4-20 mA HART
Ga/Gb Ex ia/db [ia Ga] IIC T6...T3 X
Ex ta/tb IIIC T85°C Da/Db XEx Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
4-20 mA HART
0Ex ia IIC T6...T3 Ga X
Ga/Gb Ex ia IIC T6...T3 XEx Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
NEPSI:
Ex ia IIC T6 Ga/Gb
Ex iaD 20/21 T85
Safety Instructions
Microwave Level Measurement
Ex Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
4-20 mA HART
Ex ia IIC T6...T1 Ga
Ex ia IIC T6...T1 Ga/GbEx Safety Instructions (XA) -
Micropilot FMR60, FMR62
4-20 mA HART
Ex ia IIC T6...T1 Ga/Gb
Ex ia/db [ia Ga] IIC T6...T1 Ga/GbEx Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
NEPSI:
Ex ia IIC T6 Ga
Ex ia IIC T6 Ga/Gb
Safety Instructions
Microwave Level Measurement
Ex Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
4-20 mA HART
Ex ec IIC T6...T1 Gc
Ex ic IIC T6...T1 GcEx Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
4-20 mA HART
Ga/Gb Ex ia IIC T6...T3 X
Ex ia IIIC T85°C Da/Db XEx Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
4-20 mA HART
Ex ia IIC T6...T1 Ga
Ex ia IIC T6...T1 Ga/GbEx Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
ATEX:
II 3 G Ex ec IIC T6...T1 Gc
II 3 G Ex ic IIC T6...T1 Gc
IECEx:
Ex ec IIC T6...T1 Gc
Ex ic IIC T6...T1 Gc
Safety Instructions
Microwave Level Measurement
Ex Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
Control Drawing XP/DIP
Safety Instructions
Microwave Level Measurement
Ex Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
4-20 mA HART
Ex ia/db [ia Ga] IIC T6...T1 Ga/GbEx Safety Instructions (XA) -
Bluetooth® module BT10
Suitable for Micropilot FMR5x, FMR6x and Levelflex FMP5x with 4-20 mA
HART
Certified according to:
ATEX/IECEx:
Ex ia, Ex ia/db,Ex ic, Ex ia/ic,
Ex ec, Ex ia/ec, Ex d,
Ex nA, Ex ia/nA, Ex ta, Ex ta/tb
EPL:
Ga, Ga/Gb, Gc, Ga/Gb/Gc, Da, Da/DbEx Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
NEPSI:
Ex nA IIC T6 Gc
Ex ic IIC T6 Gc
Safety Instructions
Microwave Level Measurement
Ex Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
4-20 mA HART
Ex ec IIC T6...T1 Gc
Ex ic IIC T6...T1 GcEx Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
NEPSI:
Ex ia/d [ia Ga] IIC T6 Ga/Gb
Ex tD A20/A21 IP6X T85°C
Safety Instructions
Microwave Level Measurement
Ex Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
4-20 mA HART
Ex ia IIC T6...T1 Ga
Ex ia IIC T6...T1 Ga/GbEx Safety Instructions (XA) -
Micropilot FMR60, FMR62, FMR67
Control Drawing IS
Safety Instructions
Microwave Level Measurement
Ex Safety Instructions (XA) -
Micropilot FMR60, FMR62
ATEX:
II 1/2 G Ex ia IIC T6...T1 Ga/Gb
II 1/2 G Ex ia/db [ia Ga] IIC T6...T1 Ga/Gb
IECEx:
Ex ia IIC T6...T1 Ga/Gb
Ex ia/db [ia Ga] IIC T6...T1 Ga/Gb
Safety Instructions
Microwave Level Measurement
Ex Safety Instructions (XA) -
Allgemeine bauaufsichtliche Zulassung
Micropilot FMR60, FMR62, FMR67
DIBt Z-65.16-583
Certificate (ZE) -
Herstellerbescheinigung/Manufacturer Declaration
Micropilot FMR60, FMR62, FMR67
Herstellerbescheinigung/Manufacturer Declaration
HE_00931_01.18Certificate (ZE) -
Cable gland M20 Ex d
for the Japanese market
Special Documentation (SD) -
Information for Korean market
Information for Korean market
Special Documentation (SD) -
Micropilot FMR60/62/67
Functional Safety Manual
Special Documentation
Free space radar for liquids and bulk solids with 4 to 20 mA output
signalSpecial Documentation (SD) -
Micropilot FMR50, FMR51, FMR52, FMR53, FMR54, FMR56, FMR57, FMR60,
FMR62, FMR67
Quick Setup
Micropilot FMR50, FMR51, FMR52, FMR53, FMR54, FMR56, FMR57, FMR60,
FMR62, FMR67
Quick SetupSpecial Documentation (SD) -
Bluetooth module
BT10
Accessories
Special Documentation
Accessories
Special Documentation (SD) -
Micropilot FMR6x
Heartbeat Diagnostics
Heartbeat Verification
Heartbeat Monitoring
Special Documentation
Free-space radar
Special Documentation (SD) -
Guide de sélection de mesure de niveau radar à émission libre
Liquides, solides en vrac, stockage, process et mesure transactionnelle
Publications (PU)01/19fr -
Prevent unscheduled downtimes
With fuel and chemical supply chain management in Primaries
Industry Solutions (SO)09/19English -
More efficient with the supplier-managed inventory business model
Inventory and supply chain solution across depots for a chemical
producerIndustry Solutions (SO)09/19English -
Catálogo Medición y Detección de nivel
Gama de productos para aplicaciones con líquidos y sólidos
Fields of Activities (FA)09/19Spanish -
Mesure de niveau
Aperçu des produits pour des applications dans des liquides et des
solides en vracFields of Activities (FA)03/19fr -
Level measurement
Product overview for applications in liquids and bulk solids
Fields of Activities (FA)03/17English -
Füllstandmesstechnik
Produktübersicht für Anwendungen in Flüssigkeiten und Schüttgütern
Fields of Activities (FA)03/17German -
Level measurement
Product overview for applications in liquids and bulk solids
Fields of Activities (FA)03/17English -
113 GHz
La réponse adaptée à chaque application
Votre longueur d'onde
Innovations (IN)11/16fr -
113GHZ+SU LONGITUD DE ONDA
La mejor respuesta para cada aplicación
La medición de nivel por radar soluciona diversos desafíos en diferentes
aplicaciones. La
clave para conseguir la solución perfecta es poder elegir: ofrecemos un
rango de
frecuencias adaptado a las necesidades específi cas de su aplicación.Innovations (IN)11/16Spanish -
113GHZ+Sulla vostra lunghezza d'onda
La risposta giusta per qualsiasi applicazione
La risposta giusta per qualsiasi applicazione
La misura di livello radar risolve varie problematiche connesse ad
applicazioni diverse.
La scelta dello strumento giusto è fondamentale per ottenere una
soluzione ideale: noi
vi offriamo un'ampia gamma di frequenze per soddisfare le vostre
esigenze applicative.Innovations (IN)11/16Italian -
113 ГГц
Для каждой задачи – своя рабочая частота
113 ГГц
Для каждой задачи – своя рабочая частотаInnovations (IN)11/16Russian -
Bluetooth module BT10 - checklist and Installation guide
Whatare the requirements to use the Bluetooth module BT10 for our Radar
devices?
And how do you install it? We answer these two questions in this
document.Innovations (IN)07/18German -
Module Bluetooth BT10 - checklist et guide d'installation
Quelles sont les conditions requises pour utiliser le module Bluetooth
BT10 pour nos
appareils radar ?
Comment l'installer ? Nous répondons à ces deux questions dans ce
document.Innovations (IN)06/18fr -
Bluetooth module BT10 - checklist and Installation guide
Whatare the requirements to use the Bluetooth module BT10 for our Radar
devices?
And how do you install it? We answer these two questions in this
document.Innovations (IN)06/18English -
113GHz+IHRE WELLENLÄNGE
Die richtige Antwort für jede Anwendung
Mit der Radarfüllstandmessung lassen sich eine Reihe an
Herausforderungen in verschiedensten Anwendungen lösen. Für die Suche
nach der idealen Lösung braucht es die komplette Auswahl. Wir bieten die
volle Bandbreite an verschiedenen Messfrequenzen, um spezifischen
Anwendungsanforderungen zu begegnen.Innovations (IN)02/17German -
113GHZ+YOUR WAVELENGTH
The right answer for any application
The right answer for any application
Radar level measurement solves a series of challenges in different
applications. The key toachieving the ideal solution is choice: We offer
a range of frequencies to match specific application needs.Innovations (IN)01/17English -
American version: 113GHZ+YOUR WAVELENGTH
The right answer for any application
The right answer for any application
Radar level measurement solves a series of challenges in different
applications. The key toachieving the ideal solution is choice: We offer
a range of frequencies to match specific application needs.Innovations (IN)01/17English -
Micropilot FMR 60
Füllstand-Messwertaufnehmer und Umformer ausgeführt als Kompaktgerät zur
kontinuierlichen Füllstandmessung unabhängig von wechselnden Medien,
Temperaturänderungen, Gaspolstern und Dämpfen in Behältern.Tender Text02/18German -
EDD Single, EH_HART_LE_Micropilot_0x112B_0x01_0x02_FCG, 28.03.2018 (Level, Micropilot, 0x112B)
HART,
HART Version: AnyElectronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_LE_Micropilot_0x112B_0x01_0x01, 27.04.2017 (Level, Micropilot, 0x112B)
HART,
Field Device Manager Version: R450.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FCx75_HART_LE_Micropilot_0x112B_0x01_0x01, 27.04.2017 (Level, Micropilot, 0x112B)
HART,
FC475 Version: 3.8Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_0_HART_LE_MicropilotFMR6x_0x112B_0x01_0x02, 10.08.2018 (Level, Micropilot, 0x112B)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5, 14.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_LE_MicropilotFMR6x_0x112B_0x01_0x02, 27.04.2018 (Level, Micropilot, 0x112B)
HART,
PDM Version: 6.1, 9.0.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_0_HART_LE_MicropilotFMR6x_0x112B_0x01_0x02, 24.08.2018 (Level, Micropilot, 0x112B)
HART,
AMS Version: 10.0, 10.5, 11.0, 11.1, 11.5Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, Micropilot_FMR6x_HART_FW1_00_zz_Dev_Rev_01, 27.10.2020 (Level, Micropilot, 0x112B)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 4.1 SP4, 5.0
Plant Resource Manager Version: R3.20Device Type Manager (DTM)1.10.0.807Language neutral -
Heartbeat Micropilot Build-up Detection, FMR5x and FMR6x
Animation 1920x1080 mp4 FR
Video12/17fr -
Animation Heartbeat Micropilot Foam Detection, FMR5x and FMR6x
Animation 1920x1080 mp4 FR
Video12/17fr -
113GHz Campaign
Micropilot 80GHz radar
Animation 1920x1080 mp4 FR
Video08/17fr -
Heartbeat Micropilot Build-up Detection, FMR5x and FMR6x
Animation 1920x1080 mp4 TR
Video08/17Turkish -
113GHz Campaign
complete movie
Animation 1920x1080 mp4 FR
Video08/17fr -
Heartbeat Micropilot Build-up Detection, FMR5x and FMR6x
Animation 1920x1080 mp4 EN
Video05/17English -
Animation Heartbeat Micropilot Foam Detection, FMR5x and FMR6x
Animation 1920x1080 mp4 EN
Video05/17English -
FMR6x Radar
Animation 1920x1080 mp4 EN
Video04/17English -
113GHz Campaign
complete movie
Animation 1920x1080 mp4 DE
Video04/17German -
113GHz Campaign
Micropilot 80GHz radar
Animation 1920x1080 mp4 DE
Video04/17German -
113GHz Campaign
complete movie
Animation 1920x1080 mp4 EN
Video03/17English -
113GHz Campaign
Micropilot 80GHz radar
Animation 1920x1080 mp4 EN
Video03/17English -
Cerabar, Cerabar M, Cerabar S, Levelflex, Micropilot, Micropilot S
Product Code: FMR56-, FMR57-, FMR60-, FMR62-, FMR67-, PMC11-, PMC21-, PMC71B-, PMP11-, PMP21-, PMP23-, PMP51-, PMP51B-, PMP55-, PMP71-, PMP71B-, PMP72-, PMP75-, FMR540-, FMR54-, FMR533-, FMR532-, FMR531-, FMR530-, FMR53-, FMR52-, FMR51-, FMR50-, FMP57-, FMP56-, FMP55-, FMP54-, FMP53-, FMP52-, FMP51-, FMP50-
Declaration Number: HE_01158_01.19Manufacturer DeclarationEnglish -
Micropilot
Product Code: FMR60-
Declaration Number: HE_00827_01.17
Manufacturer Specification: RoHSManufacturer DeclarationChinese -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Declaration Number: EC_00479_06.17EU DeclarationGerman , English , fr -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Declaration Number: EC_00480_05.17EU DeclarationGerman , English , fr -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Declaration Number: EC_00478_06.17EU DeclarationGerman , English , fr -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Declaration Number: EC_00477_06.17EU DeclarationGerman , English , fr -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Declaration Number: SIL_00252_01.18SIL DeclarationEnglish -
SYSTEM, Pumpenschutz, Nivotester FailSafe, Nivotester, Micropilot S, Micropilot, Liquipoint T, Liquipoint, Liquiphant T, Liquiphant S, Liquiphant M, Liquiphant FailSafe, Liquiphant, Liquicap T, Liquicap M, Levelflex, Einstabsonde, Dreistabsonde, Doppelstabsonde
Product Code: FTL70-, FTL51H-, FTL51C-, FTL51-, FTL50H-, FTL50-, FTL375P-, FTL33-, FTL325P-, FTL325N-, FTL31-, FTL260-, FTI52-, FTI51-, FTL71-, FTL80-, FTL81-, FTL825-, FTL85-, FTW23-, FTW31-, FTW32-, FTW325-, FTW33-, FTW360-, NMR81-, NMR84-, 11362Z-, 11363Z-, 11371-, 11375Z-, 11961Z-, FMI21-, FMI51-, FMI52-, FMP50-, FMP51-, FMP52-, FMP53-, FMP54-, FMP55-, FMR10-, FMR20-, FMR50-, FMR51-, FMR52-, FMR53-, FMR530-, FMR532-, FMR533-, FMR54-, FMR540-, FMR60-, FMR62-, FTC325-
Region/Country: Russia (Declaration of Conformity), Russia (TR CU)
Approval Agency: EAC
Approval Number: RU D-DE.MO10.B.05531MiscellaneousRussian -
SYSTEM, Pumpenschutz, Nivotester FailSafe, Nivotester, Micropilot S, Micropilot, Liquipoint T, Liquiphant T, Liquiphant S, Liquiphant M, Liquiphant FailSafe, Liquiphant, Liquicap T, Liquicap M, Levelflex
Product Code: FTL260-, FMP52-, FMP54-, FMR52-, FMR54-, FMP55-, FMP53-, FMR51-, FMP51-, FMR53-, FMR62-, FTL51-, FMR50-, FTL51H-, FTL50H-, FMP50-, NMR84-, FTL51C-, FMR60-, FTL71-, FTL70-, FTL31-, FTL325N-, FTL325P-, FTL33-, FTL375P-, FTL50-, FTL80-, FTL825-, FTL85-, FTW31-, FTL81-, FTW32-, FTW325-, FTW360-, NMR81-, FTI52-, FMI21-, FMI51-, FMI52-, FMR10-, FMR20-, FMR530-, FMR532-, FMR533-, FMR540-, FTC325-, FTI51-
Region/Country: Russia (Declaration of Conformity), Russia (TR CU)
Approval Agency: EAC
Approval Number: RU D-DE.MO10.B.05528MiscellaneousRussian -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Region/Country: Canada
Approval Agency: FMExplosion ProtectionEnglish -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Region/Country: Japan
Approval Agency: CML
Protection: Ex ec IIC T6 Gc, Ex ia tb IIC T6 Ga/Gb, IIC T6 Ga/Gb/Gc, IIC T6 Ga/Gb/Gc, Ex ta/tb IIIC Txxx°C Da/Db, Ex ta IIIC T500=xxx°C Da, Ex ic IIC T6 Gc, Ex ia IIIC Txxx°C Da/Db, Ex ia IIC T6 Ga/Gb, Ex ia IIC T6 GaExplosion ProtectionJapanese -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Region/Country: International (IECEx)
Approval Agency: IBExU
Protection: Ex ia IIC T6 Ga, Ex ia IIC T6 Ga/Gb, Ex ic IIC T6 Gc, Ex ta IIIC T500=xxx°C Da, Ex ta/tb IIIC Txxx°C Da/Db, Ex ec IIC T6 Gc, Ex ia tb IIC T6 Ga/Gb, IIC T6 Ga/Gb/Gc, IIC T6 Ga/Gb/GcExplosion ProtectionEnglish -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Region/Country: International (IECEx)
Approval Agency: IBExU
Protection: Ex ia IIC T6 Ga, Ex ia IIC T6 Ga/Gb, Ex ic IIC T6 Gc, Ex ta/tb IIIC Txxx°C Da/Db, Ex ec IIC T6 Gc, Ex ia tb IIC T6 Ga/Gb, IIC T6 Ga/Gb/Gc, IIC T6 Ga/Gb/GcExplosion ProtectionEnglish -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Region/Country: Brazil
Approval Agency: INMETRO
Category: zone 2, zone 0, zone 0,1
Protection: Ex d, Ex iaExplosion ProtectionPortuguese -
Micropilot
Product Code: FMR62-, FMR67-, FMR60-
Region/Country: International (IECEx)
Approval Agency: IBExU
Protection: Ex ia tb IIC T6 Ga/Gb, IIC T6 Ga/Gb/Gc, IIC T6 Ga/Gb/Gc, Ex ec IIC T6 Gc, Ex ta/tb IIIC Txxx°C Da/Db, Ex ta IIIC T500=xxx°C Da, Ex ic IIC T6 Gc, Ex ia IIC T6 Ga/Gb, Ex ia IIC T6 GaExplosion ProtectionEnglish -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Region/Country: Brazil
Approval Agency: INMETRO
Category: zone 2, zone 0, zone 0,1
Protection: Ex d, Ex iaExplosion ProtectionPortuguese -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Region/Country: USAExplosion ProtectionEnglish -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Region/Country: Japan
Approval Agency: CML
Protection: Ex ec IIC T6 Gc, Ex ia tb IIC T6 Ga/Gb, IIC T6 Ga/Gb/Gc, IIC T6 Ga/Gb/Gc, Ex ta/tb IIIC Txxx°C Da/Db, Ex ta IIIC T500=xxx°C Da, Ex ic IIC T6 Gc, Ex ia IIIC Txxx°C Da/Db, Ex ia IIC T6 Ga/Gb, Ex ia IIC T6 GaExplosion ProtectionJapanese -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Region/Country: USAExplosion ProtectionEnglish -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Region/Country: Europe (ATEX)
Approval Agency: IBExUExplosion ProtectionGerman , English , fr -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Region/Country: Europe (ATEX)
Approval Agency: IBExU
Category: II 3 G, II 1/2 D, II 1/2 G, II 1/2/3 G, II 1 G
Protection: Ex ia IIC T6 Ga, Ex ia IIC T6 Ga/Gb, Ex ic IIC T6 Gc, Ex ta/tb IIIC Txxx°C Da/Db, Ex ec IIC T6 Gc, Ex ia tb IIC T6 Ga/Gb, IIC T6 Ga/Gb/Gc, IIC T6 Ga/Gb/Gc, Ex ta IIIC T500=xxx°C DaExplosion ProtectionGerman , English -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Region/Country: Russia
Protection: Ex ia IIC T6...T3 Ga, Ex ia IIC T6...T3 Ga/Gb, Ex ia IIIC T6 Da/Db, Ex ic IIC T6...T3 Gc, Ex ic [ia Ga] IIC T6...T3 Ga/Gb/Gc, Ex nA IIC T6...T3 Gc, Ex d [ia Ga] IIC T6...T3 Ga/Gb, Ex d e [ia Ga] IIC T6...T3 Ga/Gb, Ex nA [ia Ga] IIC T6...T3 Ga/Gb/Gc, Ex ta/tb IIIC T6 Da/DbExplosion ProtectionRussian -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Region/Country:
Approval Agency:
Protection: Ex ia, Ex ta/tb, Ex ec, Ex dbExplosion Protection -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Region/Country: South Korea
Approval Agency: KTL
Protection: Ex ia IIC T6Explosion Protection -
Micropilot
Product Code: FMR62-, FMR67-, FMR60-
Region/Country: International (IECEx)
Approval Agency: IBExU
Protection: Ex ta/tb IIIC, Ex ec IIC, Ex ia/db IIC, Ex ta IIIC, Ex ic IIIC, Ex ic IIC, Ex ia IICExplosion ProtectionEnglish -
Micropilot
Product Code: FMR62-, FMR67-, FMR60-
Region/Country: USA, Canada
Approval Agency: CSAExplosion ProtectionEnglish -
Micropilot
Product Code: FMR62-, FMR67-, FMR60-
Region/Country: Europe (ATEX)
Approval Agency: IBExU
Protection: Ex ta IIIC, Ex ta/tb IIIC, Ex ec IIC, Ex ia tb IIC, Ex ic IIIC, Ex ic IIC, Ex ia IICExplosion ProtectionGerman , English -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Region/Country: Brazil
Approval Agency: INMETRO
Category: zone 2, zone 0, zone 0,1
Protection: Ex d, Ex iaExplosion ProtectionPortuguese -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Region/Country: Europe (ATEX)
Approval Agency: IBExU
Category: II 3 G, II 1/2 D, II 1/2 G, II 1/2/3 G, II 1 G
Protection: Ex ia IIC T6 Ga, Ex ia IIC T6 Ga/Gb, Ex ic IIC T6 Gc, Ex ta/tb IIIC Txxx°C Da/Db, Ex ec IIC T6 Gc, Ex ia tb IIC T6 Ga/Gb, IIC T6 Ga/Gb/Gc, IIC T6 Ga/Gb/GcExplosion ProtectionGerman , English -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Region/Country: China
Approval Agency: NEPSI
Protection: Ex ia IIC T6 Ga, Ex ia IIC T6 Ga/Gb, Ex ic IIC T6 Gc, Ex tD A20/A21 IP6X Txxx°C, Ex d [ia Ga] IIC T6 Ga/Gb, Ex iaD 20/21 Txxx°CExplosion ProtectionChinese -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Region/Country: South Korea
Approval Agency: KTL
Protection: Ex d [ia] IIC T6Explosion Protection -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Region/Country: Germany
Approval Agency: DIBt
Approval Number: Z-65.16-583Overfill PreventionGerman -
Levelflex, Micropilot
Product Code: FMR67-, FMR62-, FMR60-, FMR56-, FMR54-, FMR53-, FMR52-, FMR51-, FMR50-, FMP57-, FMP56-, FMP55-, FMP54-, FMP53-, FMP52-, FMP51-, FMP50-
Radio Equipment -
Levelflex, Micropilot
Product Code: FMR67-, FMR62-, FMR60-, FMR57-, FMR56-, FMR54-, FMR53-, FMR52-, FMR51-, FMP57-, FMP56-, FMP55-, FMP54-, FMP53-, FMP52-, FMP51-, FMP50-, FMR50-
Radio EquipmentEnglish -
Micropilot
Product Code: FMR60-, FMR67-
Radio EquipmentEnglish -
Levelflex, Micropilot
Product Code: FMP50-, FMP51-, FMP52-, FMP53-, FMP54-, FMP55-, FMP56-, FMP57-, FMR50-, FMR51-, FMR52-, FMR53-, FMR60-, FMR62-
Radio EquipmentJapanese -
Levelflex, Micropilot
Product Code: FMR67-, FMR62-, FMR60-, FMR56-, FMR54-, FMR53-, FMR52-, FMR51-, FMR50-, FMP57-, FMP56-, FMP55-, FMP54-, FMP53-, FMP52-, FMP51-, FMP50-, FMR57-
Region/Country: USARadio EquipmentEnglish -
Levelflex, Micropilot
Product Code: FMR67-, FMR62-, FMR60-, FMR56-, FMR54-, FMR53-, FMR52-, FMR51-, FMR50-, FMP57-, FMP56-, FMP55-, FMP54-, FMP53-, FMP52-, FMP51-, FMP50-
Radio Equipment -
Micropilot, Micropilot S, Minicap, Nivector, Prosonic M, Prosonic S, Prosonic T, Pumpenschutz, Solicap M, Solicap S, Soliphant M, Soliphant T, SYSTEM, Doppelstabsonde, Dreistabsonde, Einstabsonde, Levelflex, Liquicap M, Liquicap T, Liquiphant, Liquiphant FailSafe, Liquiphant M, Liquiphant S, Liquipoint, Liquipoint T, LIQUITREND
Product Code: FTL51C-, FTL51B-, FTL51-, FTL50H-, FTL50-, FTL41-, FTL33-, FTL31-, FTI77-, FTI56-, FTI55-, FTI52-, FTI51-, FTI26-, FTC968Z-, FTC262-, FTC260-, FMU44-, FMU43-, FTL51H-, FTL62-, FTL64-, FTL70-, FTL71-, FTL80-, FTL81-, FTL85-, FTM20-, FTM21-, FTM50-, FTM51-, FTM52-, FTW23-, FTW31-, FTW32-, FTW33-, NMR81-, NMR84-, QMW43-, FMU42-, 11362Z-, 11363Z-, 11371-, 11375Z-, 11961Z-, FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-, FMI21-, FMI51-, FMI52-, FMP50-, FMP51-, FMP52-, FMP53-, FMP54-, FMP55-, FMU41-, FMU40-, FMU30-, FMR67-, FMR62-, FMR60-, FMR57-, FMR56-, FMR540-, FMR54-, FMR532-, FMR53-, FMR52-, FMR51-, FMR50-, FMR20-, FMR10-, FMP57-, FMP56-
Approval Agency: TÜVPressure EquipmentGerman , English -
Micropilot
Product Code: FMR62-, FMR67-, FMR60-
Region/Country: Canada (CRN)
Approval Agency: CRNPressure EquipmentEnglish -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Region/Country: Russia (GOST)
Approval Agency: Rosstandart
Approval Number: DE.C.29.004.A № 68686MetrologyRussian -
Micropilot, Micropilot S, SYSTEM
Product Code: NMR84-, NMR81-, FMR67-, FMR62-, FMR60-, FMR57-, FMR56-, FMR540-, FMR54-, FMR533-, FMR532-, FMR530-, FMR53-, FMR52-, FMR51-, FMR50-, FMR20-, FMR10-
Region/Country: Belarus
Approval Agency: BEL
Approval Number: 10554MetrologyRussian -
Micropilot, Micropilot S, SYSTEM
Product Code: NMR84-, NMR81-, FMR67-, FMR62-, FMR60-, FMR57-, FMR56-, FMR540-, FMR54-, FMR533-, FMR532-, FMR531-, FMR530-, FMR53-, FMR52-, FMR51-, FMR50-, FMR20-, FMR10-
Region/Country: Uzbekistan
Approval Agency: UZS
Approval Number: 02.6926MetrologyRussian -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Region/Country: International
Approval Agency: TÜVSafety Integrity Level (SIL)German -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Region/Country: International
Approval Agency: RM RSMarineRussian -
Micropilot
Product Code: FMR62-, FMR67-, FMR60-
Region/Country: International
Approval Agency: ABSMarineEnglish -
Micropilot
Product Code: FMR62-, FMR67-, FMR60-
Region/Country: International
Approval Agency: DNVGLMarineGerman , English -
Micropilot
Product Code: FMR60-, FMR62-, FMR67-
Region/Country: South Korea
Approval Agency: KRMarine
Accessories / Spare parts
-
-
Nr 19 Order code 71115175
Housing filter Brass/Ni GT19/20, 1 set
Consists of: 2x filter plug brass nickel, pressure compensation filter. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 17 Order code 71115176
Set housing securing clamps
Usage: housing GT18/GT19/GT20, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 20 Order code 71110292
Cover GT19 PBT, sight glass, EPDM
Material: plastics PBT-FR sight glas PC. O-ring EPDM, PTFE coated. Usage: FHX50, FMP50/FMP51/FMP52/ FMP53/FMP54/FMP55/FMP56/FMP57, FMR50/ FMR51/FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.
-
Nr 20 Order code 71110293
Cover GT19 PBT, EPDM
Material: plastics PBT, metallized. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.
-
-
-
Nr 25 Order code 71110295
Cover GT19 PBT, Terminal Ex, EPDM
Material: plastics PBT, metallized. Usage: terminal compartment, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.
-
Nr 25 Order code 71185518
Cover GT19 PBT, Terminal, OVP, EPDM
Material: plastic PBT, metallizied. O-ring EPDM, PTFE coated. Usage: terminal compartment, for overvoltage protection, not for Ex d/XP. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.
-
-
-
Order code 71450381
Plug M12, IP66/68 NEMA4X/6P, ProToF
For electrical connection. Usage: FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57,FMR50/FMR51/FMR52/FMR53/ FMR54/FMR57, FMR60/FMR62/FMR67.
-
-
-
Nr 20 Order code 71110297
Cover GT20 Alu, sight glass, HNBR
Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Nr 20 Order code 71110299
Cover GT20 Alu, HNBR
Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 25 Order code 71110301
Cover GT20 Alu, Terminal Ex, HNBR
Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: terminal compartment, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Nr 25 Order code 71110302
Cover GT20 Alu, Terminal Ex d, HNBR
Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: terminal compartment Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Nr 25 Order code 71185517
Cover GT20 Alu, Terminal, OVP, HNBR
Material: aluminium. O-ring EPDM, PTFE coated. Usage: terminal compartment, for overvoltage protection, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 65 Order code 71110303
Sealing set GT18/GT19/GT20, EPDM, HNBR
Consists of: O-ring 88.5x3.53 EPDM/PTFE, cover electronics compartment, housing GT19. O-Ring 88.5x3.53 NBR, cover electronics compartment, housing GT18, GT20. O-ring 91.67x3.53 EPDM/PTFE, cover terminal compartment, housing GT19. O-Ring 91.67x3.53 NBR, cover terminal compartment, housing GT18, GT20. O-ring 50.39x3.53 EPDM/PTFE, housing/sensor. FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Order code 71128617
Overvoltage protection (OVP10),1-Channel
4-20mA HART. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Order code 71128619
Overvoltage protection (OVP20),2-Channel
4-20mA HART, PROFIBUS PA, FOUNDATION Fieldbus, Imp./Freq./Switch output. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 34 Order code 71350681
I/O module 2-wire, 4-20mA, HART, Ex, V3
Non-Ex, Ex. 1x current output HART. Version 3. Usage: FMR60/FMR62/FMR67.
-
Nr 34 Order code 71350683
I/O module,2-wr., 4-20mA,HART,PFS, Ex V2
Non-Ex, Ex. 1x current output HART, 1x PFS. PFS=switch output. Version 2. Usage: FMR60/FMR62/FMR67.
-
Nr 34 Order code 71350687
I/O mod. Level, 2-wr.2x4-20mA,HART,Ex,V3
Non-Ex, Ex. Current output, 4-20mA HART + 4-20mA analog. Version 3. Usage: FMR60/FMR62/FMR67.
-
Nr 34 Order code 71364026
I/O mod.Level,2-wr.4-20mA,HART,Ex,LP,V3
Version 3. Not for Ex d/XP. LP=low powered. 1x current output HART. Usage: FMR60/FMR62/FMR67.
-
-
-
Nr 37 Order code 71110280
Terminal set 2-wire, I/O module
Consists of: 4x terminal 2-pole, green. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 40 Order code 71248380
Spare part kit FHX50
Retrofit kit. Consists of: transmitter board, ribbon cable, cable gland, M12 bushing, VA. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Prowirl 200, Promass 200, Promag 200, Prosonic Flow 200.
-
-
-
Order code
Remote display FHX50 please order with separate order structure.
-
-
-
Nr 40 Order code 71206552
-
Nr 40 Order code 71206554
-
Nr 40 Order code 71206555
-
Nr 40 Order code 71206556
-
-
-
Nr 30 Order code XPF0038-
-
-
-
Nr 40 Order code XPD0024-
Display module, SD02, push buttons
For housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, t-mass 150, Promag 200, Prowirl 200. Consists of: Display SD02, helix cable, ribbon cable, connector cover.
-
Nr 40 Order code XPD0025-
Display module, SD03, Touch Control
For housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. Consists of: Display SD03 illuminated, ribbon cable, connector cover.
-
-
-
Order code 71377355
Bluetooth module (BT10)
Module for wireless data communication. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.
-
Order code 71336522
-
Order code 71162242
Weather prot. cover GT18/GT19/GT20, 316L
Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/ FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Order code XPRFID-
-
-
-
Nr 57 Order code 52014047
Sealing ring G1-1/2, 48x55 FA, 5 pcs.
Process gasket DIN7603-A. Usage: process connection, FMI21, FMI51/FMI52, FTI51/FTI52, FTI55, FTW31/FTW32, FMP51/FMP57, FMR60/FMR62/FMR67, Sliding sleeve G1-1/2 316L (52003665), 316L,3.1 (52011882), FTL51, FTL71,FTL81, AlloyC4 (52003666), FTL51, FTL71.
-